5.1.2
Logged-In LED Indications
59021-06 A
Logging In
Error
Port diagnostics are indicated by the Logged-In LED for each port as shown in
Figure
The Logged-In LED has three indications:
If a Logged-In LED shows an error indication, review the alarm log for messages
regarding the affected port. You can inspect the alarm log using the Alarm data
tab in SANbox Manager faceplate display or the Show Alarm command. Pertinent
alarm log messages will point to one or more of the following conditions:
Logged in - Continuous illumination.
Logging in - Flashes at roughly once per second as shown in
Error - Flashes at roughly twice per second as shown in
E_Port isolation
Excessive port errors
5-1.
Figure 5-2. Logged-In LED Indications
1 second
Figure 5-1. Logged-In LED
5 – Diagnostics/Troubleshooting