EP1AGX ALTERA [Altera Corporation], EP1AGX Datasheet - Page 153

no-image

EP1AGX

Manufacturer Part Number
EP1AGX
Description
Section I. Arria GX Device Data Sheet
Manufacturer
ALTERA [Altera Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1AGX20CF484C3
Manufacturer:
XILINX
0
Part Number:
EP1AGX20CF484C6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1AGX20CF484C6
Manufacturer:
ALTERA
0
Part Number:
EP1AGX20CF484C6N
Manufacturer:
ALTERA
Quantity:
672
Part Number:
EP1AGX20CF484C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1AGX20CF484C6N
Manufacturer:
ALTERA
Quantity:
8 000
Part Number:
EP1AGX20CF484C6N
Manufacturer:
ALTERA
Quantity:
40
Part Number:
EP1AGX20CF484I6N
Manufacturer:
ALTERA10
Quantity:
60
Part Number:
EP1AGX20CF484I6N
Manufacturer:
ALTERA
Quantity:
40
Part Number:
EP1AGX20CF484I6N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP1AGX20CF780C6N
Manufacturer:
ALTERA31
Quantity:
135
Part Number:
EP1AGX20CF780C6N
Manufacturer:
ALTERA
Quantity:
35
Chapter 4: DC and Switching Characteristics
I/O Timing Model
Table 4–45. Timing Measurement Methodology for Input Pins
Clock Network Skew Adders
Table 4–46. Clock Network Specifications
Default Capacitive Loading of Different I/O Standards
© December 2009 Altera Corporation
Differential SSTL-18 Class II
1.5-V differential HSTL Class I
1.5-V differential HSTL Class II
1.8-V differential HSTL Class I
1.8-V differential HSTL Class II
LVDS
LVPECL
Notes to
(1) Input buffer sees no load at buffer input.
(2) Input measuring point at buffer input is 0.5 V
(3) Output measuring point is 0.5 V
(4) Input edge rate is 1 V/ns.
(5) Less than 50-mV ripple on V
(6) V
Clock skew adder
EP1AGX20/35
Clock skew adder
EP1AGX50/60
Clock skew adder
EP1AGX90
Note to
(1) This is in addition to intra-clock network skew, which is modeled in the Quartus II software.
CCPD
Table
Table
= 2.97 V, less than 50-mV ripple on V
Name
(1)
I/O Standard
4–46:
4–45:
(1)
(1)
The Quartus II software models skew within dedicated clock networks such as global
and regional clocks. Therefore, the intra-clock network skew adder is not specified.
Table 4–46
registers in the Arria GX device.
See
Table 4–47. Default Loading of Different I/O Standards for Arria GX Devices (Part 1 of 2)
LVTTL
LVCMOS
2.5 V
Inter-clock network, same side
Inter-clock network, entire chip
Inter-clock network, same side
Inter-clock network, entire chip
Inter-clock network, same side
Inter-clock network, entire chip
Table 4–47
CCIO
CC
and V
at internal node.
specifies the intra clock skew between any two clock networks driving any
CCPD
I/O Standard
, V
for default capacitive loading of different I/O standards.
CCIO
Description
CCIO
CCINT
V
and V
.
1.660
1.375
1.375
1.660
1.660
2.325
3.135
CCIO
= 1.15 V with less than 30-mV ripple.
CCPD
(V)
, V
Measurement Conditions
CCINT
= 1.15 V.
V
0.830
0.688
0.688
0.830
0.830
REF
(Note
(V)
Min
Capacitive Load
1), (2), (3),
Edge Rate (ns)
0
0
0
Typ
1.660
1.375
1.375
1.660
1.660
0.100
0.100
(4)
(Part 2 of 2)
± 100
± 100
± 110
± 50
Max
± 50
± 55
Arria GX Device Handbook, Volume 1
Measurement Point
Units
Units
VMEAS (V)
ps
ps
ps
ps
ps
ps
pF
pF
pF
0.6875
0.6875
1.1625
1.5675
0.83
0.83
0.83
4–31

Related parts for EP1AGX