HD6417034B RENESAS [Renesas Technology Corp], HD6417034B Datasheet - Page 414

no-image

HD6417034B

Manufacturer Part Number
HD6417034B
Description
32-Bit RISC Microcomputer
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417034BVFN20
Manufacturer:
RENESAS
Quantity:
101
Part Number:
HD6417034BVFN20
Manufacturer:
RENESAS
Quantity:
482
Part Number:
HD6417034BVFW20
Manufacturer:
MITSUBISHI
Quantity:
101
Part Number:
HD6417034BVXN20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface (SCI)
In receiving, the SCI operates as follows:
1. The SCI monitors the receive data line. When it detects a start bit (0), the SCI synchronizes
2. Receive data is shifted into RSR in order from the LSB to the MSB.
3. The parity bit and stop bit are received. After receiving these bits, the SCI makes the following
2.
Figure 13.8 shows an example of SCI receive operation in asynchronous mode.
Table 13.11 Receive Error Conditions and SCI Operation
Receive Error
Overrun error
Framing error
Parity error
Rev. 7.00 Jan 31, 2006 page 388 of 658
REJ09B0272-0700
internally and starts receiving.
checks:
a. Parity check: The number of 1s in the receive data must match the even or odd parity
b. Stop bit check: The stop bit value must be 1. If there are two stop bits, only the first stop bit
c. Status check: RDRF must be 0 so that receive data can be loaded from RSR into RDR.
Note:
After setting RDRF to 1, if the receive-data-full interrupt enable bit (RIE) is set to 1 in SCR,
the SCI requests a receive-data-full interrupt (RXI). If one of the error flags (ORER, PER, or
FER) is set to 1 and the receive-data-full interrupt enable bit (RIE) in SCR is also set to 1, the
SCI requests a receive-error interrupt (ERI).
setting of the O/E bit in SMR.
is checked.
If these checks all pass, the SCI sets RDRF to 1 and stores the received data in RDR. If one
of the checks fails (receive error), the SCI operates as indicated in table 13.11.
When a receive error flag is set, further receiving is disabled. The RDRF bit is not
set to 1. Be sure to clear the error flags.
Abbreviation
ORER
FER
PER
Condition
RDRF is still set to 1 in SSR
Stop bit is 0
even/odd parity setting in SMR
Receiving of next data ends while
Parity of receive data differs from
Data Transfer
Receive data not loaded
from RSR into RDR
Receive data loaded from
RSR into RDR
Receive data loaded from
RSR into RDR

Related parts for HD6417034B