S9S08SG8E2VTG Freescale Semiconductor, S9S08SG8E2VTG Datasheet - Page 263

no-image

S9S08SG8E2VTG

Manufacturer Part Number
S9S08SG8E2VTG
Description
8-bit Microcontrollers - MCU 9S08 UC W/ 8K 0.25UM SGF
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S08SG8E2VTG

Rohs
yes
Core
S08
Processor Series
MC9S08SG8
Data Bus Width
8 bit
Maximum Clock Frequency
40 MHz
Program Memory Size
8 KB
Data Ram Size
8 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 5.5 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
TSSOP-16
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
12
Interface Type
SCI, SPI
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
16
Number Of Timers
2
Program Memory Type
Flash
Supply Voltage - Max
5.5 V
Supply Voltage - Min
2.7 V
All TPM interrupts are listed in
that can block the interrupt request from leaving the TPM and getting recognized by the separate interrupt
processing logic.
The TPM module will provide a high-true interrupt signal. Vectors and priorities are determined at chip
integration time in the interrupt module so refer to the user’s guide for the interrupt module or to the chip’s
complete documentation for details.
16.6.2
For each interrupt source in the TPM, a flag bit is set upon recognition of the interrupt condition such as
timer overflow, channel-input capture, or output-compare events. This flag may be read (polled) by
software to determine that the action has occurred, or an associated enable bit (TOIE or CHnIE) can be set
to enable hardware interrupt generation. While the interrupt enable bit is set, a static interrupt will generate
whenever the associated interrupt flag equals one. The user’s software must perform a sequence of steps
to clear the interrupt flag before returning from the interrupt-service routine.
TPM interrupt flags are cleared by a two-step process including a read of the flag bit while it is set (1)
followed by a write of zero (0) to the bit. If a new event is detected between these two steps, the sequence
is reset and the interrupt flag remains set after the second step to avoid the possibility of missing the new
event.
16.6.2.1
The meaning and details of operation for TOF interrupts varies slightly depending upon the mode of
operation of the TPM system (general purpose timing functions versus center-aligned PWM operation).
The flag is cleared by the two step sequence described above.
16.6.2.1.1
Normally TOF is set when the timer counter changes from 0xFFFF to 0x0000. When the TPM is not
configured for center-aligned PWM (CPWMS=0), TOF gets set when the timer counter changes from the
terminal count (the value in the modulo register) to 0x0000. This case corresponds to the normal meaning
of counter overflow.
Freescale Semiconductor
Description of Interrupt Operation
Interrupt
Timer Overflow Interrupt (TOF) Description
CHnF
TOF
Normal Case
Enable
CHnIE
Local
TOIE
Table 16-11
MC9S08SG8 MCU Series Data Sheet, Rev. 7
Counter overflow
Channel event
Table 16-11. Interrupt Summary
Source
which shows the interrupt name, the name of any local enable
Set each time the timer counter reaches its terminal
count (at transition to next count value which is
usually 0x0000)
An input capture or output compare event took
place on channel n
Description
Timer/PWM Module (S08TPMV3)
259

Related parts for S9S08SG8E2VTG