IS66WVE1M16BLL-55BLI-TR ISSI, IS66WVE1M16BLL-55BLI-TR Datasheet - Page 14

no-image

IS66WVE1M16BLL-55BLI-TR

Manufacturer Part Number
IS66WVE1M16BLL-55BLI-TR
Description
SRAM 16Mb 1M x 16 55ns Pseudo SRAM
Manufacturer
ISSI
Datasheet

Specifications of IS66WVE1M16BLL-55BLI-TR

Rohs
yes
Memory Size
16 Mbit
Organization
1 Mbit x 16
Access Time
55 ns
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
Maximum Operating Current
35 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA-48
Memory Type
Psuedo
Factory Pack Quantity
2500
Software Access Sequence
Notes :
Rev. A | Feb. 2012
Figure 6 : Configuration Register Write
UB#/LB#
Address
DQ15
DQ0-
WE#
The contents of the CR can be read or modified using a software access sequence. The
nature of this access mechanism can potentially eliminate the need for the ZZ# ball.
If the software-access mechanism is used, ZZ# can simply be tied to VDDQ; the port line
typically used for ZZ# control purposes will no longer be required. However, ZZ# should
not be tied to VDDQ if the system will use DPD; DPD cannot be enabled or disabled using
the software-access sequence.
The CR is loaded using a four-step sequence consisting of two READ operations followed
by two WRITE operations (see Figure 6). The READ sequence is virtually identical
except that an asynchronous READ is performed during the fourth operation (see
Figure 7).
The address used during all READ and WRITE operations is the highest address of the
PSRAM device being accessed (FFFFFh); the content of this address is not changed by
using the software-access sequence. The data bus is used to transfer data into or out of
bit[15:0] of the CR.
Writing to the CR using the software-access sequence modifies the function of the ZZ#
ball. After the software sequence loads the CR, the level of the ZZ# ball no longer enables
PAR operation. PAR operation is updated whenever the software-access sequence loads
a new value into the CR. This ZZ# functionality will remain active until the next time the
device is powered up. The operation of the ZZ# ball is not affected if the software-access
sequence is only used to read the contents of the CR. Use of the software-access sequence
does not affect the performance of standard (ZZ#-controlled) CR loading.
1. CR : 0000h
CE#
OE#
Read
ADDRESS
MAX
OUTPUT
DATA
www.issi.com
Read
ADDRESS
MAX
OUTPUT
DATA
- SRAM@issi.com
Write
ADDRESS
MAX
*Note1
IS66WVE1M16BLL
Write
ADDRESS
MAX
VALUE IN
CR
14