MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 17

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
2.3
FIGURE 2-3:
© 2008 Microchip Technology Inc.
METER OUTPUT
There are two outputs of the PIC18F2520, the CF calibration pulse and the RS-232
interface containing the register information. This meter design isolates both of these
outputs using digital isolator U
to the neutral line of 220V, a DC-DC converter is also included to isolate the power from
P8, the output header. The output header, when used with the USB Interface Module,
interfaces the meter to both the PC and the LCD on the USB interface module for
output display.
Meter Output Diagram.
RS-232 RX, TX
3-Phase Energy Meter
CF Output Pulse
V
Main Board
DD
GNDA
GNDA
DC-DC
Converter
Opto-Isolator
Opto-Isolator
13
and opto-isolator U
U17
EEPROM
GNDB
U13
U10
V
GNDB
U17
DD
P8
10
. With the A
P1
USB Interface Module
GND
Hardware
being referenced
DS51643B-page 13

Related parts for MCP3909RD-3PH1