MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 47

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
5.3.2
FIGURE 5-3:
© 2008 Microchip Technology Inc.
Enable Calibration Mode
CAL_CONTROL register
PHy_VA_GLSB contents
Put meter in Calibration
by setting bit 0 and 1 of
Configuration C1 (VB
Set MODE1 register
ENERGY_W_RAW,
PHy_W_GLSB, and
bits and LINE_CYC
based equations in
CFNUM, CFDEN,
Calculate & Write
Read contents of
and IB at PF=1)
PHy_W_RAW
Section 5.3.3
CAL_MODE
Main Flow Chart for Calibration
bit 1 low
register
to 1
Is
?
YES
Main Calibration Flow Chart.
NO
YES
Power Offset
This Phase
Proceed to
Flow For
Active
YES
Begin Calibration
for This Phase
Is this Phase
compensation
being set as
Is this Phase
the standard
Phase delay
matched to
being gain
standard
Calibrate
Calibrate
phase?
phase?
Offset?
Power
Active
?
NO
NO
NO
YES
NO
Proceed to
YES
RMS Flow
For This
Proceed to Gain Matching
Phase
Phase Delay Flow For This
Error, must Cal CF with
Proceed to Active Power
YES
Standard Phase
Meter Calibration
YES
phase been
NO
calibrated
Calibrate
standard
Phase
for CF
RMS?
Has a
adjust
Flow
?
DS51643B-page 43
End This
Phase
NO

Related parts for MCP3909RD-3PH1