MCP3909RD-3PH1 Microchip Technology, MCP3909RD-3PH1 Datasheet - Page 48

REF DESIGN MCP3909 3PH ENGY MTR

MCP3909RD-3PH1

Manufacturer Part Number
MCP3909RD-3PH1
Description
REF DESIGN MCP3909 3PH ENGY MTR
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909RD-3PH1

Main Purpose
Power Management, Energy/Power Meter
Embedded
No
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Primary Attributes
3-Ph, 220 VAC, In Case, LCD, USB, GUI
Secondary Attributes
Opto-Isolated Interface for Safety
Operating Voltage
220 V
Operating Current
5 A
Description/function
Energy Meter
For Use With/related Products
MCP3909
Lead Free Status / RoHS Status
Not applicable / Not applicable
MCP3909 3-Phase Energy Meter Reference Design
DS51643B-page 44
5.3.3
The following equations represent the proper method for calculating the calibration and
correction factors after configuration C1. The PC calibration software handles these
calculations automatically.
The following equations only apply when calibrating a standard phase.
The first 4 equations apply for calculating the proper output frequency of the CF output.
See Figure 5-3 for meter input conditions.
EQUATION 5-1:
EQUATION 5-2:
EQUATION 5-3:
EQUATION 5-4:
The gain matching registers for the standard phase need to be set to the following val-
ues when calibrating a standard phase:
EQUATION 5-5:
The following equations apply for calculating the proper GLSB registers when calibrat-
ing both a standard phase, and a non-standard phase. See flow chart for meter input
conditions.
Note:
Note:
CFDEN
Equations for Configuration C1 Calibration
Convert to 8-bit signed integer for compatibility with 18F2520 register and
firmware calculations.
Convert to 16-bit signed integer for compatibility with 18F2520 register and
firmware calculations.
CFNUM
=
LOG
-------------------------------------------------------------------------------------------------------------------------- -
CF_IMP_S
=
LINE_CYC_NUM
--------------------------------------------------------------- - 2
2
---------------------------------------- LINE_CYC_NUM 256
--------------------------------------------------------- -
LINE_CYC_NUM 256
Line Freq 128
32
ENERGY_W_L_RAW
PHY_W_GAIN
2
----------------------------------------
Line Freq 128
32
CF_IMP_S
=
CF_IMP_S
Meter Constant
------------------------------------ -
LOG(2)
=
3600
=
--------------------------------------------------------- -
2
ENERGY_W_L_RAW
LINE_CYC
16 384
,
© 2008 Microchip Technology Inc.
V
----------- -
1000
CFDEN
B
I
B
32768
+
1