MCP3909EV-MCU16 Microchip Technology, MCP3909EV-MCU16 Datasheet - Page 4

EVALUATION BOARD FOR MCP3909

MCP3909EV-MCU16

Manufacturer Part Number
MCP3909EV-MCU16
Description
EVALUATION BOARD FOR MCP3909
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909EV-MCU16

Number Of Adc's
2
Number Of Bits
16
Sampling Rate (per Second)
15k
Data Interface
Serial
Inputs Per Adc
1 Differential
Input Range
±1 V
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
MCP3909
Silicon Manufacturer
Microchip
Application Sub Type
ADC
Kit Application Type
Data Converter
Silicon Core Number
MCP3909
Kit Contents
Board
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MCP3909 / dsPIC33F 3-Phase Energy Meter Reference Design
Chapter 5. PC Software
Chapter 6. Meter Communications Protocol
Appendix A. Schematics and Layouts
Appendix B. Bill Of Materials (BOM)
Appendix C. Power Calculation Theory
DS51723A-page 4
5.1 Overview And Installation ............................................................................. 43
5.2 Establish Communication ............................................................................. 44
5.3 Basic Parameters Output Screen ................................................................. 45
5.4 Phase A/B/C Harmonic Output Screen ........................................................ 45
5.5 Distortion Rate .............................................................................................. 46
5.6 Harmonic Power ........................................................................................... 46
5.7 Energy Accumulation ................................................................................... 47
5.8 Calibration Step 1 - Reset All Calibration ..................................................... 47
5.9 Linearity Calibration ...................................................................................... 48
5.10 Apparent Power Calibration ....................................................................... 49
5.11 Phase Lag Calibration ................................................................................ 50
6.1 Introduction ................................................................................................... 51
6.2 Test Connection Command .......................................................................... 52
6.3 Total Data Request ...................................................................................... 52
6.4 Status Register ............................................................................................. 54
6.5 Harmonic Content Command ....................................................................... 54
6.6 Total Harmonic Distortion (THD) Command ................................................ 55
6.7 Start Energy Measurement Command ......................................................... 56
6.8 Stop Energy Measurement Command ......................................................... 56
6.9 Harmonic Power Command ......................................................................... 57
6.10 Calibrate Meter Voltage/current Command ................................................ 58
6.11 Calibrate Phase Lag Command ................................................................. 59
6.12 Calibrate Apparent Power Command ......................................................... 59
6.13 Calibrate Energy Pulse Command ............................................................. 60
6.14 Reset All Meter Calibration Values Command ........................................... 60
6.15 Calibrate Meter Constant (Energy Pulse Output Constant) ....................... 61
A.1 Introduction .................................................................................................. 63
A.2 Schematics And Pcb Layout ........................................................................ 63
C.1 Overview ...................................................................................................... 75
C.2 Synchronous Sampling And Quasi-synchronous Sampling ........................ 75
C.3 The Harmonic Analysis Algorithm Of Quasi-synchronous Sampling ........... 82
C.4 Measuring The Voltage/current Rms Value And Power Using Quasi-synchro-
C.5 Measuring Frequency .................................................................................. 87
C.6 Improving Measurement Precision Of Quasi-synchronous Sampling Algorithm
C.7 Measuring Secondary Parameters .............................................................. 91
C.8 Apparent Power Of Each Phase And Total Apparent Power ....................... 91
C.9 Power Factor Of Each Phase And Total Power Factor ............................... 91
nous Sampling Algorithm ........................................................................ 84
................................................................................................................. 89
© 2009 Microchip Technology Inc.

Related parts for MCP3909EV-MCU16