Specifications of MPC561MZP56

Core Processor
PowerPC
Core Size
32-Bit
Speed
56MHz
Connectivity
CAN, EBI/EMI, SCI, SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
64
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 2.7 V
Data Converters
A/D 32x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 125°C
Package / Case
388-BGA
Controller Family/series
POWER 5xx
No. Of I/o's
56
Ram Memory Size
31KB
Cpu Speed
56MHz
No. Of Timers
32
Embedded Interface Type
QSPI, SCI, UART
No. Of Pwm Channels
12
Rohs Compliant
No
Processor Series
MPC5xx
Core
PowerPC
Data Bus Width
32 bit
Data Ram Size
32 KB
Interface Type
CAN, JTAG, QSPI, SCI, SPI, UART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
56
Number Of Timers
22
Operating Supply Voltage
2.6 V to 5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
2 (10 bit, 32 Channel)
For Use With
MPC564EVB - KIT EVAL FOR MPC561/562/563/564
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC561MZP56
Manufacturer:
FREESCALE
Quantity:
852
Part Number:
MPC561MZP56
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MPC561MZP56
Manufacturer:
FREESCALE
Quantity:
852
Company:
Part Number:
MPC561MZP56
Quantity:
13
Part Number:
MPC561MZP56R2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
L-Bus to U-Bus Interface (L2U)
11.7.1
L-bus show cycles are disabled during reset and must be configured by setting the LSHOW[0:1] bits in the
L2U_MCR.
11.7.2
When show cycles are enabled in the L2U module, there is a performance penalty on the L-bus. This
occurs because the L2U module does not support more than one access being processed at any time. To
ensure that only one access at a time is processed, and not lose an L-bus access that would have been show
cycled, the L2U module will arbitrate for the L-bus whenever it is processing any access. This L-bus
arbitration will prevent any other L-bus master from starting a cycle that might turn out to be a qualifiable
L-bus show cycle.
For L-bus show cycles, the minimum performance impact on the L-bus will be three clocks. This minimum
impact assumes that the L-bus slave access is a 1-clock access, and the L2U module acquires immediate
bus grant on the U-bus. The L2U has to wait two clocks before completing the show cycle on the U-Bus,
thus using up five clocks for the complete process.
A retried access on the L-bus (no address acknowledge) that qualifies to be show cycled, will be accepted
when it is actually acknowledged. This will cause a 1-clock delay before an L-bus master can retry the
access on the L-bus, because the L2U module will release L-bus one clock later.
L2U asserts the internal bus request signal on the U-bus for a minimum of two clocks when starting a show
cycle on the U-bus.
11.7.3
The L2U module behaves as both a master and a slave on the U-bus during show cycles. The L2U starts
the U-bus transfer as a bus master and then completes the address phase and data phase of the cycle as a
slave. The L2U follows U-bus protocol of in-order termination of the data phase.
The USIU can control the start of show cycles on the U-bus by asserting the no-show cycle indicator. This
will cause the L2U module to release the U-bus for at least one clock before retrying the show cycle.
11.7.4
The L2U performs the following sequence of actions for an L-bus-write show cycle.
11-10
1. Arbitrates for the L-bus to prevent any other L-bus cycles from starting
Programming Show Cycles
Performance Impact
Show Cycle Protocol
L-Bus Write Show Cycle Flow
Table 11-3
LSHOW
00
01
10
11
shows the configurations of the LSHOW[0:1] bits.
MPC561/MPC563 Reference Manual, Rev. 1.2
Show address and data of all L-bus space read and write cycles
Table 11-3. L2U_MCR LSHOW Modes
Show address and data of all L-bus space write cycles
Reserved (Disable L-bus show cycles)
Disable L-bus show cycles
Action
Freescale Semiconductor