MCF5282CVF80J Freescale Semiconductor, MCF5282CVF80J Datasheet - Page 185

no-image

MCF5282CVF80J

Manufacturer Part Number
MCF5282CVF80J
Description
IC MPU 512K FLASH 256MAPBGA
Manufacturer
Freescale Semiconductor
Series
MCF528xr
Datasheet

Specifications of MCF5282CVF80J

Core Processor
Coldfire V2
Core Size
32-Bit
Speed
80MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, SPI, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
150
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
256-MAPBGA
Processor Series
MCF528x
Core
ColdFire V2
3rd Party Development Tools
JLINK-CF-BDM26, EWCF
Development Tools By Supplier
NNDK-MOD5282-KIT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5282CVF80J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
9.7.4.7
If the LOLRE bit in the SYNCR is set, a loss of lock condition asserts reset. Reset reinitializes the LOCK
and LOCKS flags. Therefore, software must read the LOL bit in the reset status register (RSR) to
determine if a loss of lock caused the reset. See
To exit reset in PLL mode, the reference must be present, and the PLL must achieve lock.
In external clock mode, the PLL cannot lock. Therefore, a loss of lock condition cannot occur, and the
LOLRE bit has no effect.
9.7.4.8
The LOCEN bit in the SYNCR enables the loss of clock detection circuit to monitor the input clocks to
the phase and frequency detector (PFD). When either the reference or feedback clock frequency falls
below the minimum frequency, the loss of clock circuit sets the sticky LOCS flag in the SYNSR.
9.7.4.9
The clock module can assert a reset when a loss of clock or loss of lock occurs. When a loss-of-clock
condition is recognized, reset is asserted if the LOCRE bit in SYNCR is set. The LOCS bit in SYNSR is
cleared after reset. Therefore, the LOC bit must be read in RSR to determine that a loss of clock condition
occurred. LOCRE has no effect in external clock mode.
To exit reset in PLL mode, the reference must be present, and the PLL must acquire lock.
Reset initializes the clock module registers to a known startup state as described in
Map and
9.7.4.10 Alternate Clock Selection
Depending on which clock source fails, the loss-of-clock circuit switches the system clocks source to the
remaining operational clock. The alternate clock source generates the system clocks until reset is asserted.
As
The PLL remains in SCM until the next reset. When the PLL is operating in SCM, the system frequency
depends on the value in the RFD field. The SCM system frequency stated in electrical specifications
assumes that the RFD has been programmed to binary 000. If the loss-of-clock condition is due to PLL
failure, the PLL reference becomes the system clocks source until the next reset, even if the PLL regains
and relocks.
Freescale Semiconductor
1
Table 9-9
The LOC circuit monitors the reference and feedback inputs to the PFD. See
External
Clock
Mode
PLL
Registers.”
PLL Loss of Lock Reset
Loss of Clock Detection
Loss of Clock Reset
shows, if the reference fails, the PLL goes out of lock and into self-clocked mode (SCM).
In external clock mode, the loss of clock circuit is disabled.
System Clock Source
Before Failure
External clock
PLL
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
Table 9-9. Loss of Clock Summary
Selected by LOC Circuit
Reference Failure Alternate Clock
PLL self-clocked mode
Section 29.4.2, “Reset Status Register
NOTE
None
1
Until Reset
Figure
Selected by LOC Circuit Until Reset
PLL Failure Alternate Clock
9-5.
PLL reference
Section 9.6, “Memory
NA
(RSR).”
Clock Module