ATMEGA169-16AI SL710 Atmel, ATMEGA169-16AI SL710 Datasheet - Page 278

IC AVR MCU 16K 16MHZ IND 64TQFP

ATMEGA169-16AI SL710

Manufacturer Part Number
ATMEGA169-16AI SL710
Description
IC AVR MCU 16K 16MHZ IND 64TQFP
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA169-16AI SL710

Core Processor
AVR
Core Size
8-Bit
Speed
16MHz
Connectivity
SPI, UART/USART, USI
Peripherals
Brown-out Detect/Reset, LCD, POR, PWM, WDT
Number Of I /o
54
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
512 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TQFP, 64-VQFP
For Use With
ATAVRBFLY - KIT EVALUATION AVR BUTTERFLYATSTK502 - MOD EXPANSION AVR STARTER 500
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
ATMEGA16916ASL710
Reading the Fuse and Lock
Bits
Reading the Signature Bytes
Reading the Calibration Byte
278
ATmega169/V
The algorithm for reading the Fuse and Lock bits is as follows (refer to “Programming
the Flash” on page 273 for details on Command loading):
1. A: Load Command “0000 0100”.
2. Set OE to “0”, BS2 to “0” and BS1 to “0”. The status of the Fuse Low bits can
3. Set OE to “0”, BS2 to “1” and BS1 to “1”. The status of the Fuse High bits can
4. Set OE to “0”, BS2 to “1”, and BS1 to “0”. The status of the Extended Fuse bits
5. Set OE to “0”, BS2 to “0” and BS1 to “1”. The status of the Lock bits can now be
6. Set OE to “1”.
Figure 124. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to “Programming the
Flash” on page 273 for details on Command and Address loading):
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS to “0”. The selected Signature byte can now be read at
4. Set OE to “1”.
The algorithm for reading the Calibration byte is as follows (refer to “Programming the
Flash” on page 273 for details on Command and Address loading):
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte, 0x00.
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.
4. Set OE to “1”.
now be read at DATA (“0” means programmed).
now be read at DATA (“0” means programmed).
can now be read at DATA (“0” means programmed).
read at DATA (“0” means programmed).
DATA.
Fuse Low Byte
Extended Fuse Byte
Fuse High Byte
Lock Bits
BS2
BS2
0
1
0
1
BS1
0
1
DATA
2514P–AVR–07/06