NUMICRO-SDK Nuvoton Technology Corporation of America, NUMICRO-SDK Datasheet - Page 128

KIT EVAUATION NUC100/120/130/140

NUMICRO-SDK

Manufacturer Part Number
NUMICRO-SDK
Description
KIT EVAUATION NUC100/120/130/140
Manufacturer
Nuvoton Technology Corporation of America
Series
NuMicro™r
Type
MCUr
Datasheets

Specifications of NUMICRO-SDK

Contents
Board, Cable, CD, Nu-Link
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
NUC100, NUC120, NUC130, NUC140

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NUMICRO-SDK
Manufacturer:
Nuvoton Technology Corporation
Quantity:
135
Part Number:
NUMICRO-SDK
Manufacturer:
NuvoTon
Quantity:
69
Brown-Out Detector Control Register (BODCR)
Partial of the BODCR control registers values are initiated by the flash configuration and partial
bits are write-protected bit. Programming write-protected bits needs to write “59h”, “16h”, “88h” to
address 0x5000_0100 to disable register protection. Reference the register REGWRPROT at
address GCR_BA+0x100
Register
BODCR
Bits
[31:8]
[7]
[6]
[5]
LVR_EN
31
23
15
7
NuMicro™ NUC100 Series Technical Reference Manual
Descriptions
Reserved
LVR_EN
BOD_OUT
BOD_LPM
Offset
GCR_BA+0x18
BOD_OUT
30
22
14
6
BOD_LPM
Reserved
Low Voltage Reset Enable (write-protection bit)
The LVR function reset the chip when the input power voltage is lower than LVR circuit
setting. LVR function is enabled in default.
1 = Enabled Low Voltage Reset function – After enabling the bit, the LVR function will
be active with 100uS delay for LVR output stable. (default).
0 = Disabled Low Voltage Reset function
This bit is the protected bit. It means programming this needs to write “59h”, “16h”,
“88h” to address 0x5000_0100 to disable register protection. Reference the register
REGWRPROT at address GCR_BA+0x100
Brown Out Detector output status
1 = Brown Out Detector output status is 1. It means the detected voltage is lower than
BOD_VL setting. If the BOD_EN is 0, BOD function disabled , this bit always responds
0
0 = Brown Out Detector output status is 0. It means the detected voltage is higher than
BOD_VL setting or BOD_EN is 0
Brown Out Detector Low power Mode (write-protection bit)
1 = Enable the BOD low power mode
0 = BOD operate in normal mode (default)
The BOD consumes about 100uA in normal mode, the low power mode can reduce the
current to about 1/10 but slow the BOD response.
This bit is the protected bit. It means programming this needs to write “59h”, “16h”,
“88h” to address 0x5000_0100 to disable register protection. Reference the register
R/W
R/W
29
21
13
5
Description
Brown Out Detector Control Register
BOD_INTF
28
20
12
4
- 128 -
Reserved
Reserved
Reserved
BOD_RSTEN
27
19
11
3
Publication Release Date: Dec. 22, 2010
26
18
10
2
BOD_VL
25
17
9
1
Revision V1.06
Reset Value
0x0000_008X
BOD_EN
24
16
8
0

Related parts for NUMICRO-SDK