NUMICRO-SDK Nuvoton Technology Corporation of America, NUMICRO-SDK Datasheet - Page 129

KIT EVAUATION NUC100/120/130/140

NUMICRO-SDK

Manufacturer Part Number
NUMICRO-SDK
Description
KIT EVAUATION NUC100/120/130/140
Manufacturer
Nuvoton Technology Corporation of America
Series
NuMicro™r
Type
MCUr
Datasheets

Specifications of NUMICRO-SDK

Contents
Board, Cable, CD, Nu-Link
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
NUC100, NUC120, NUC130, NUC140

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NUMICRO-SDK
Manufacturer:
Nuvoton Technology Corporation
Quantity:
135
Part Number:
NUMICRO-SDK
Manufacturer:
NuvoTon
Quantity:
69
[4]
[3]
[2:1]
[0]
NuMicro™ NUC100 Series Technical Reference Manual
BOD_INTF
BOD_RSTEN
BOD_VL
BOD_EN
REGWRPROT at address GCR_BA+0x100.
Brown Out Detector Interrupt Flag
1 = When Brown Out Detector detects the VDD is dropped down through the voltage of
BOD_VL setting or the VDD is raised up through the voltage of BOD_VL setting, this
bit is set to 1 and the brown out interrupt is requested if brown out interrupt is enabled.
0 = Brown Out Detector does not detect any voltage draft at VDD down through or up
through the voltage of BOD_VL setting.
Software can write 1 to clear this bit to zero.
Brown Out Reset Enable (write-protection bit)
1 = Enable the Brown Out “RESET” function
While the Brown Out Detector function is enabled (BOD_EN high) and BOD reset
function is enabled (BOD_RSTEN high), BOD will assert a signal to reset chip when
the detected voltage is lower than the threshold (BOD_OUT high).
0 = Enable the Brown Out “INTERRUPT” function
While the BOD function is enabled (BOD_EN high) and BOD interrupt function is
enabled (BOD_RSTEN low), BOD will assert an interrupt if BOD_OUT is high. BOD
interrupt will keep till to the BOD_EN set to 0. BOD interrupt can be blocked by
disabling the NVIC BOD interrupt or disabling BOD function (set BOD_EN low).
The default value is set by flash controller user configuration register config0 bit[20].
This bit is the protected bit. It means programming this needs to write “59h”, “16h”,
“88h” to address 0x5000_0100 to disable register protection. Reference the register
REGWRPROT at address GCR_BA+0x100.
Brown Out Detector Threshold Voltage Selection (write-protection bits)
The default value is set by flash controller user configuration register config0 bit[22:21]
This bit is the protected bit. It means programming this needs to write “59h”, “16h”,
“88h” to address 0x5000_0100 to disable register protection. Reference the register
REGWRPROT at address GCR_BA+0x100.
Brown Out Detector Enable (write-protection bit)
The default value is set by flash controller user configuration register config0 bit[23]
1 = Brown Out Detector function is enabled
0 = Brown Out Detector function is disabled
This bit is the protected bit. It means programming this needs to write “59h”, “16h”,
“88h” to address 0x5000_0100 to disable register protection. Reference the register
REGWRPROT at address GCR_BA+0x100.
BOV_VL[1]
1
1
0
0
- 129 -
BOV_VL[0]
1
0
1
0
Publication Release Date: Oct 22, 2010
Brown out voltage
4.5V
3.8V
2.7V
2.2V
Revision V1.06