Specifications of C200H-DA001

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
NAME MNEMONIC
BCD-TO- BINARY
(@)BIN(23)
DOUBLE BCD-TO-DOUBLE
BINARY (@)BINL(58)
BINARY-TO- BCD
(@)BCD(24)
DOUBLE BINARY-TO-DOUBLE
BCD
(@)BCDL(59)
BIT COUNTER

(@)BCNT(67)
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “
used.
An instruction marked with “


” is an expansion instruction. These instructions must be assigned function codes before they can be
” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
SYMBOL
BIN(23)
BCD(24)
BCDL(59)
BINL(58)
BCNT(67)
S
R
R
R
SB
S
S
S
R
N
R
PROGRAMMING INSTRUCTIONS
S + 1
FUNCTION
Converts 4-digit, BCD data in source word (S) into
16-bit binary data, and outputs converted data to result
word (R).
Converts the BCD value of the two source words (S:
starting word) into binary and outputs the converted
data to the two result words (R: starting word).
S + 1
Converts binary data in source word (S) into BCD, and
outputs converted data to result word (R).
Counts the number of ON bits in one or more words.
(BIN)
Converts the binary value of the two source words (S:
starting word) into eight digits of BCD data, and outputs
the converted data to the two result words.
(BCD)
S
S
S
S
x16
x16
x16
x16
0
1
2
3
DATA CONVERSION INSTRUCTIONS
x10
x10
x10
x10
(BCD)
0
1
2
3
R
x10
x10
x10
x10
0
1
2
3
R + 1
R + 1
R
101
(BIN)
R
R
x16
x16
x16
x16
0
1
2
3

Related parts for C200H-DA001