C200H-DA001 Omron, C200H-DA001 Datasheet - Page 31

no-image

C200H-DA001

Manufacturer Part Number
C200H-DA001
Description
2PT-D/A:12-BIT
Manufacturer
Omron
Datasheet

Specifications of C200H-DA001

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
28
SPECIAL I/O MODULES
B7A INTERFACE MODULE
Performance Specifications
Note:
Connectable B7A Link Terminals
Input Terminals
Output Terminals
PART NUMBER
I/O points
Transmission distance
Transmission delay
Internal current
consumption
External power supply
External ower su
(
(see note 2)
Weight
Word allocations
TYPE
Screw terminals
Screw terminals
Modular
Modular
PLC connectors
PLC connectors
TYPE
Screw terminals
Screw terminals
Modular
Modular
PLC connectors
PLC connectors
t 2)
1. The transmission delay is changed by using the DIP switch.
2. The value of the external power supply does not include the value required by the B7A Link Terminal.
ly
TRANSMISSION DELAY
Standard (19.2 ms)
Standard (19.2 ms)
High-speed (3 ms)
High s eed (3 ms)
Standard (19.2 ms)
High-speed (3 ms)
Standard (19.2 ms)
High-speed (3 ms)
TRANSMISSION DELAY
Standard (19.2 ms)
Standard (19.2 ms)
High-speed (3 ms)
High s eed (3 ms)
Standard (19.2 ms)
High-speed (3 ms)
Standard (19.2 ms)
High-speed (3 ms)
C200H-B7AI1
B7A INTERFACE MODULES
16 points or 15
points and 1 error
input
500 m max. if power is supplied to the
Interface Module and B7A Link Terminal
separately.
100 m max. if power is supplied to the
Interface Module and B7A Link Terminal
from a single power supply.
19.2 ms typical, 31 ms max.
5 VDC, 100 mA max.
12 to 24 VDC 10%
0.01 A min.
200 g max.
Same as I/O Modules (in order mounted).
C200H-B7AO1
16 output points
0.03 A min.
PART NUMBER
B7A-T6
B7AS-T6
B7A-T6
B7AS-T6
B7A-T6D2
B7A-T6D7
B7A-T
B7A-T
PART NUMBER
B7A-R6
B7AS-R6
B7A-R6
B7AS-R6
B7A-R6A52
B7A-R6A57
B7A-R
B7A-R








E3
E8
A
A




1
6


C200H-B7A12
GROUP-2 B7A INTERFACE MODULES
32 input points or
30 input points and 2
error inputs
Standard:
500 m max. using separate power supplies.
100 m max. using a common power supply.
High-speed:
100 m max. using separate power supplies.
50 m max. using a common power supply.
If shielded cable is not used, the maximum transmission distance is 10 m regardless of
whether a common or separate power supplies are used.
Standard:
High-speed:
0.05 A min.
300 g max.
The words allocated to Group-2 B7A Interface Modules are determined by I/O number set on
the Modules. Words 030 to 049 allocated according to I/O number setting. Modules with 32
I/O points are allocated two words; Modules with 64 I/O points are allocated four words.
1
6
1
6
3
8
1
6
19.2 ms typical, 31 ms max.
3 ms typical, 5 ms max. (see note 1)
C200H-B7A02
32 output points
0.06 A min.
C200H-B7A21
16 output points and
16 input points or
15 input points + 1
error input
0.05 A min.
C200H-B7A22
32 output points and
32 input points or
30 input points + 2
error inputs
0.08 A min.

Related parts for C200H-DA001