C200H-DA001 Omron, C200H-DA001 Datasheet - Page 121

no-image

C200H-DA001

Manufacturer Part Number
C200H-DA001
Description
2PT-D/A:12-BIT
Manufacturer
Omron
Datasheet

Specifications of C200H-DA001

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
118
PROGRAMMING INSTRUCTIONS
SYSTEM PROCESSING INSTRUCTIONS
NAME MNEMONIC
FAILURE ALARM
(@)FAL(06)
SEVERE FAILURE ALARM
FALS(07)
CYCLE TIME

(@)SCAN(18)
TERMINAL MODE

(@)TERM(48)
WATCHDOG TIMER
REFRESH
(@)WDT(94)
I/O REFRESH
(@)IORF(97)
GROUP-2 HIGH-DENSITY I/O
REFRESH

(@)MPRF(61)
INTELLIGENT IO READ
(@)IORD

INTELLIGENT IO WRITE
(@)IORW

PROTOCOL MACRO
(@)PMCR

CARD MACRO
(@)CMCR

An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with “
An instruction marked with “


” is an expansion instruction. These instructions must be assigned function codes before they can be used.
” is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
SYMBOL
FALS(07)
FAL(06
WDT(94)
SCAN(18)
TERM(48)
IORF(97)
MPRF(61)
CMCR
PMCR
IOWR
IORD
------
------
------
------
------
St
Mi
E
C
S
D
)
St
C
D
C
D
C
D
S
S
S
E
N
N
T
FUNCTION
Assigns a failure alarm code to the given execution
condition. This code is generated as an error code
whenever the instruction is executed.
A fatal version of FAL(06). When a FALS(07) instruction
is executed the CPU is stopped and the number is gen-
erated as an error code.
Sets the minimum cycle time, Mi, in tenths of millisec-
onds. The possible setting range is from 0 to 999.0 ms.
Shifts the Programming Console to TERMINAL mode.
Sets the maximum and minimum limits for the watchdog
timer (normally 0 to 130 ms). New limits:
Maximum time = 130 + (100 x T)
Minimum time = 130 + (100 x (T--1))
Can refresh I/O words allocated to CPU or Expansion
I/O Racks and Special I/O Modules.
Refreshes I/O words allocated to Group-2 High-density
I/O Modules.
Reads data of more than one word from an ASCII
Module, etc.
Writes data of more than one word from a PLC’s CPU
to an ASCII Module.
By calling the send/receive sequence (protocol data)
registered in the Communication Board connected to a
PLC’s CPU, data can be sent to or received from
another personal computer that has RS-232C.
Reads or writes files in the memory card of the PC Card
Module.

Related parts for C200H-DA001