User Memory Area
The C200HX, C200HG, and C200HE have a User Memory (UM) area allocation function. This function allows the use of the ladder pro-
gram area of the UM as a fixed expansion DM area and I/O comment area. The function is enabled with the SYSMAC Support Software
(SSS), SYSWIN, or the Programming Console. Only SSS can be used to designate any part of the ladder program area as an I/O com-
ment area (i.e., the Programming Console cannot be used to designate any part of the ladder program area as an I/O comment area.
C200HX/HG/HE Memory Area Structure
Ladder program
area
I/O comment area
Fixed expansion DM
area
System reserved
area
PLC Setup area
Normal DM area
DM 1000 to DM 2599 can be used as a normal DM if DM 7000 to DM 8599 are set as a Special I/O Module default area with the PLC Setup. DM 6000 to DM 6030 are used
exclusively as an error log area.
Unlike the normal DM area, nothing can be written to the fixed expansion DM area using ladder programming.
The capacity of a ladder program will decrease if the size of the fixed expansion DM area and the total capacity of the I/O comments increase.
The C200HX, C200HG, and C200HE do not have a fixed expansion DM area or I/O comment area before shipping. The user must allocate these areas in the UM according to
the application.
Normal Data Memory (DM) 6,144 words
Special I/O
Module
default area
A user program is stored in the ladder program area. If part of the UM is used as a fixed expansion DM area or I/O comment area, the capacity
of the ladder program area storing the user program will be reduced accordingly.
I/O comments are stored in the I/O comment area. The I/O comments can be stored with a program. The I/O comments can be monitored
without loading the comment, just as with conventional comments.
The default values of the Special I/O Module, Programmable Terminal, the character string of the Programmable Terminal, and operation data
are stored in the fixed expansion DM area. By changing the I/O monitor present value of the Programming Console or using the DM edit transfer
operation of the Ladder Support Software, the default values can be written to DM 7000 to DM 9999.
The system reserved area is used by the system only.
The settings required for the operation of the PLC are stored in the PLC Setup area.
The user can freely use the normal DM as a data area for arithmetic operations. If the Special I/O Module is used, DM 1000 to DM 2599 will be a
Special I/O Module default area.
Error
log
area
Fixed DM (512
words)
PLC
Setup
area
System
reserved
area
Fixed
expansion
DM area
(0 to 3,000
words)
Possible ROM area
I/O
comment
area
Built-in UM (32K words max.)
Ladder program area
SPECIFICATIONS, CHARACTERISTICS
13