EP1S10F484I6 Altera, EP1S10F484I6 Datasheet - Page 327

IC STRATIX FPGA 10K LE 484-FBGA

EP1S10F484I6

Manufacturer Part Number
EP1S10F484I6
Description
IC STRATIX FPGA 10K LE 484-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheets

Specifications of EP1S10F484I6

Number Of Logic Elements/cells
10570
Number Of Labs/clbs
1057
Total Ram Bits
920448
Number Of I /o
335
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Family Name
Stratix
Number Of Logic Blocks/elements
10570
# I/os (max)
335
Frequency (max)
450.05MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
10570
Ram Bits
920448
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
484
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S10F484I6
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1S10F484I6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S10F484I6
Manufacturer:
ALTERA
0
Part Number:
EP1S10F484I6
0
Part Number:
EP1S10F484I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S10F484I6N
Manufacturer:
XILINX
0
Part Number:
EP1S10F484I6N
Manufacturer:
ALTERA
0
Altera Corporation
July 2005
frequency, then the output frequency starts at a higher value than desired
as the PLL locks. If the system cannot tolerate this, the clkena signal can
disable the output clocks until the PLL locks.
The pfdena signals control the phase frequency detector (PFD) output
with a programmable gate. If you disable the PFD, the VCO operates at
its last set value of control voltage and frequency with some long-term
drift to a lower frequency. The system continues running when the PLL
goes out of lock or the input clock is disabled. By maintaining the last
locked frequency, the system has time to store its current settings before
shutting down. You can either use your own control signal or a clkloss
status signal to trigger pdfena.
The clkena signals control the enhanced PLL regional and global
outputs. Each regional and global output port has its own clkena signal.
The clkena signals synchronously disable or enable the clock at the PLL
output port by gating the outputs of the g and l counters. The clkena
signals are registered on the falling edge of the counter output clock to
enable or disable the clock without glitches.
Figure 1–7
PLL can remain locked independent of the clkena signals since the loop-
related counters are not affected. This feature is useful for applications
that require a low power or sleep mode. Upon re-enabling, the PLL does
not need a resynchronization or relock period. The clkena signal can
also disable clock outputs if the system is not tolerant to frequency
overshoot during resynchronization.
The extclkena signals work in the same way as the clkena signals, but
they control the external clock output counters (e0, e1, e2, and e3). Upon
re-enabling, the PLL does not need a resynchronization or relock period
unless the PLL is using external feedback mode. In order to lock in
external feedback mode, the external output must drive the board trace
back to the FBIN pin.
shows the waveform example for a PLL clock port enable. The
General-Purpose PLLs in Stratix & Stratix GX Devices
Stratix Device Handbook, Volume 2
1–17

Related parts for EP1S10F484I6