28119 Parallax Inc, 28119 Datasheet - Page 97

KIT UNDERSTANDING SIGNALS

28119

Manufacturer Part Number
28119
Description
KIT UNDERSTANDING SIGNALS
Manufacturer
Parallax Inc
Datasheet

Specifications of 28119

Lead Free Status
Contains lead
Accessory Type
Oscilloscope
Interface Type
USB
For Use With/related Products
BASIC Stamp® 2 and Board of Education
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
281197-2
Manufacturer:
TE
Quantity:
20 000
Part Number:
281197-2
Manufacturer:
MOLEX
Quantity:
2 500
Using the External Trigger with 38kHzInfraredwithVaryingFrequency.bs2
' Understanding Signals - 38kHzInfraredwithVaryingFrequency.bs2
' 38 kHz infrared signal with detector feedback
' {$STAMP BS2}
' {$PBASIC 2.5}
DO
LOOP
HIGH 0
FREQOUT 7,3,38500
FREQOUT 7,1,38500
FREQOUT 7,1,38500
FREQOUT 7,2,38500
FREQOUT 7,2,38500
FREQOUT 7,1,38500
FREQOUT 7,1,38500
FREQOUT 7,2,38500
FREQOUT 7,1,38500
LOW 0
PAUSE 20
Configure your OPTAscope with the following settings. Note: to set the external
trigger at 10%, press the T button at the top left corner of the Plot Area, click the
right T button to move it back.
Point the IR LED and IR detector towards each other.
Connect the External Trigger TTL probe to P0 using a jumper wire.
Run the program 38kHzInfraredwithVaryingFrequency.bs2.
CH1
CH2
Horizontal Dial
Trigger Source
Trigger Edge
Trigger Mode
Run / Stop Mode
Trigger Voltage
Autoscale
1 V / division
2 V / division
1 ms / division
External at 10%
N/A
Normal
Continuous
N/A
On
Figure 7-8:
OPTAscope
configuration for
capturing infrared
signals