HD64F3664BPV Renesas Electronics America, HD64F3664BPV Datasheet - Page 244

MCU 3/5V 32K,PB-FREE 42-DIP

HD64F3664BPV

Manufacturer Part Number
HD64F3664BPV
Description
MCU 3/5V 32K,PB-FREE 42-DIP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3664BPV

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
29
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
42-DIP (0.600", 15.24mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Section 14 Serial Communication Interface 3 (SCI3)
14.4.4
Figure 14.7 shows an example of operation for reception in asynchronous mode. In serial
reception, the SCI operates as described below.
1. The SCI3 monitors the communication line. If a start bit is detected, the SCI3 performs
2. If an overrun error occurs (when reception of the next data is completed while the RDRF flag
3. If a parity error is detected, the PER bit in SSR is set to 1 and receive data is transferred to
4. If a framing error is detected (when the stop bit is 0), the FER bit in SSR is set to 1 and receive
5. If reception is completed successfully, the RDRF bit in SSR is set to 1, and receive data is
Rev. 6.00 Mar. 24, 2006 Page 214 of 412
REJ09B0142-0600
Serial
data
RDRF
FER
LSI
operation
User
processing
internal synchronization, receives data in RSR, and checks the parity bit and stop bit.
is still set to 1), the OER bit in SSR is set to 1. If the RIE bit in SCR3 is set to 1 at this time, an
ERI interrupt request is generated. Receive data is not transferred to RDR.
RDR. If the RIE bit in SCR3 is set to 1 at this time, an ERI interrupt request is generated.
data is transferred to RDR. If the RIE bit in SCR3 is set to 1 at this time, an ERI interrupt
request is generated.
transferred to RDR. If the RIE bit in SCR3 is set to 1 at this time, an RXI interrupt request is
generated. Continuous reception is possible because the RXI interrupt routine reads the receive
data transferred to RDR before reception of the next receive data has been completed.
Figure 14.7 Example SCI3 Operation in Reception in Asynchronous Mode
Serial Data Reception
1
Start
bit
0
D0
D1
Receive
1 frame
data
(8-Bit Data, Parity, One Stop Bit)
D7
Parity
0/1
bit
RXI request
Stop
bit
1
Start
bit
0
D0
RDRF
cleared to 0
RDR data read
1 frame
D1
Receive
data
D7
Parity
0/1
bit
Stop
bit
0
0 stop bit
detected
Mark state
(idle state)
1
ERI request in
response to
framing error
Framing error
processing

Related parts for HD64F3664BPV