DF36034GFPJ Renesas Electronics America, DF36034GFPJ Datasheet - Page 439

MCU 3/5V 32K J-TEMP POR&LVD 64-L

DF36034GFPJ

Manufacturer Part Number
DF36034GFPJ
Description
MCU 3/5V 32K J-TEMP POR&LVD 64-L
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of DF36034GFPJ

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SSU
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
45
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F36034GFPJ
HD64F36034GFPJ
19.2
The low-voltage detection circuit has the following registers.
19.2.1
LVDCR is used to enable or disable the low-voltage detection circuit, set the detection levels for
the LVDR function, enable or disable the LVDR function, and enable or disable generation of an
interrupt when the power-supply voltage rises above or falls below the respective levels.
Table 19.1 shows the relationship between the LVDCR settings and select functions. LVDCR
should be set according to table 19.1.
Bit
7
6 to 4
3
2
1
Low-voltage-detection control register (LVDCR)
Low-voltage-detection status register (LVDSR)
Bit Name
LVDE
LVDSEL
LVDRE
LVDDE
Register Descriptions
Low-Voltage-Detection Control Register (LVDCR)
Initial
Value
0*
All 1
0*
0*
0
Section 19 Power-On Reset and Low-Voltage Detection Circuits (Optional)
R/W
R/W
R/W
R/W
R/W
Description
LVD Enable
0: The low-voltage detection circuit is not used (In
1: The low-voltage detection circuit is used
Reserved
These bits are always read as 1 and cannot be modified.
LVDR Detection Level Select
0: Reset detection voltage is 2.3 V (typ.)
1: Reset detection voltage is 3.6 V (typ.)
When the falling or rising voltage detection interrupt is
used, reset detection voltage of 2.3 V (typ.) should be
used. When only a reset detection interrupt is used, reset
detection voltage of 3.6 V (typ.) should be used.
LVDR Enable
0: Disables the LVDR function
1: Enables the LVDR function
Voltage-Fall-Interrupt Enable
0: Interrupt on the power-supply voltage falling below the
1: Interrupt on the power-supply voltage falling below the
standby mode)
selected detection level disabled
selected detection level enabled
Rev. 4.00 Mar. 15, 2006 Page 405 of 556
REJ09B0026-0400

Related parts for DF36034GFPJ