DF2505FC26V Renesas Electronics America, DF2505FC26V Datasheet - Page 128

IC H8S/2505 MCU FLASH 144QFP

DF2505FC26V

Manufacturer Part Number
DF2505FC26V
Description
IC H8S/2505 MCU FLASH 144QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2500r
Datasheets

Specifications of DF2505FC26V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
26MHz
Connectivity
I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
104
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Section 4 Exception Handling
Table 4.4
Legend:
1:
0:
⎯:
4.5
Interrupts are controlled by the interrupt controller. The interrupt controller has two interrupt
control modes and can assign interrupts other than NMI to eight priority/mask levels to enable
multiplexed interrupt control. For details, see section 5, Interrupt Controller.
Interrupt exception handling is conducted as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
4.6
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state.
Trap instruction exception handling is conducted as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
Rev. 6.00 Sep. 24, 2009 Page 80 of 928
REJ09B0099-0600
Interrupt Control Mode
0
2
(EXR) are saved to the stack.
from the vector table to the PC, and program execution begins from that address.
(EXR) are saved to the stack.
from the vector table to the PC, and program execution starts from that address.
Set to 1
Cleared to 0
Retains value prior to execution
Interrupt Exception Handling
Trap Instruction Exception Handling
State of CCR and EXR after Trace Exception Handling
I
Trace exception handling cannot be used.
1
CCR
UI
I2 to I0
EXR
0
T

Related parts for DF2505FC26V