XR20M1172IL32-F Exar Corporation, XR20M1172IL32-F Datasheet - Page 41

no-image

XR20M1172IL32-F

Manufacturer Part Number
XR20M1172IL32-F
Description
IC UART FIFO I2C/SPI 64B 32QFN
Manufacturer
Exar Corporation
Datasheet

Specifications of XR20M1172IL32-F

Number Of Channels
2, DUART
Package / Case
32-VFQFN Exposed Pad
Features
*
Fifo's
64 Byte
Protocol
RS485
Voltage - Supply
1.62 V ~ 3.63 V
With Auto Flow Control
Yes
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Data Rate
16 Mbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
1.62 V
Supply Current
250 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
No. Of Channels
2
Uart Features
Tx/Rx FIFO Counters
Supply Voltage Range
1.62V To 3.63V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
QFN
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR20M1172IL32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
REV. 1.0.1
EFR[4]: Enhanced Function Bits Enable
Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 4-5, MCR bits 5-7, TCR,
TLR and DLD to be modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the
new values. This feature prevents legacy software from altering or overwriting the enhanced functions once
set. Normally, it is recommended to leave it enabled, logic 1.
EFR[5]: Special Character Detect Enable
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts HIGH at the programmed HALT level. RTS# will return LOW when FIFO data falls below the
programmed RESUME level. The RTS# output must be asserted (LOW) before the auto RTS can take effect.
RTS# pin will function as a general purpose output when hardware flow control is disabled.
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, see
4.21.1
Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 4-5, MCR bits 5-
7, and DLD are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 4-5,
MCR bits 5-7, and DLD are set to a logic 0 to be compatible with ST16C550 mode (default).
Logic 1 = Enables the above-mentioned register bits to be modified by the user.
Logic 0 = Special Character Detect Disabled (default).
Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= ‘10’) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= ‘01’) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5.
Logic 0 = Automatic RTS flow control is disabled (default).
Logic 1 = Enable Automatic RTS flow control.
Logic 0 = Automatic CTS flow control is disabled (default).
Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts HIGH.
Data transmission resumes when CTS# returns LOW.
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write
Table
8.
41
TWO CHANNEL I2C/SPI UART WITH 64-BYTE FIFO
XR20M1172

Related parts for XR20M1172IL32-F