990XCP98000 SQUARE D, 990XCP98000 Datasheet - Page 221

no-image

990XCP98000

Manufacturer Part Number
990XCP98000
Description
QUANTUM CPU BATTERY FOR S
Manufacturer
SQUARE D
Datasheet

Specifications of 990XCP98000

Rohs Compliant
YES
Battery Capacity
1800mAh
Battery Technology
Lithium
Battery Voltage
3V
Battery Terminals
Connector
Weight
0.12lb
(1) Products by our partner Prosoft Technology (e-mail: prosoft@prosoft-technology.com).
Modbus Plus network
Single or redundant
copper cable
Fiber optic cable
Token ring
1 Mbps
Twisted pair
- Reading/writing of
variables
- Global Data service
- Peer Cop service
- Distributed I/O (DIO)
service
ProWORX,
Concept, and
Unity Pro CPUs
Unity Pro
Concept
ProWORX 32
1300…3800 mA
depending on 140 CPU
model 780 mA for 140
NOM
140CPU
1 integrated port
140NOM2pp00
2/9, 2/19 and 6/74
AS-Interface
actuator/sensor bus
2-wire unshielded cable
Master/slave, M2 profile
(AS-Interface V1)
167 kbps
Ribbon cable
- Standard addressing
with 31 slaves
(4I/4O “discrete”)
- Local diagnostics
(slave devices, channel
status, etc.)
250 mA
140EIA92100
6/63
Modbus SL bus
Single copper cable
Master/slave
19.2 kbps
Shielded twisted pair
cable
Modbus slave protocol
- Reading/writing of PLC
variables
- Programming
- Download
- 1 or 2 RS 232/485 ports
depending on model
Modbus master protocol
- Max. 247 slaves
1300…3800 mA
depending on 140 CPU
model 780 mA for 140
NOM
140CPU1 or 2
integrated ports
140NOM2pp00
2/9, 2/19 and 6/74
Profibus DP V1 bus
Single RS 485 cable
Class 1 master
9.6 kbps…12 Mbps
depending on distance
(1200…100 m without
repeaters)
Shielded twisted pair or
fiber optic cable
- Cyclic exchanges
(1536 discrete
inputs/1536 discrete
outputs)
- Acyclic communication
for parameter
transmission (in parallel
with cyclic exchanges)
- Management of fallback
modes
- “Sync and Freeze”
modes
- Extended diagnostics
Unity Pro
Concept V2.6 (min.)
ProWORX 32
Configuration software:
Prosoft Configuration
Builder (PCB) (1)
1000 mA
PTQPDPMV1
(1)
6/79
Single RS 485 cable
(full-duplex)
Generation 4 master
500 kbps
Shielded twisted pair or
fiber optic cable
- Cyclic I/O exchanges
(256 subscriber, 4096 I/O)
- Configuration check
- PCP V1.5 or V2.0
protocol depending on
model
- Remote bus technology
CPUs
140 CPU 113 03/
434 12A/534 14B
Concept V2.5 (min.)
Configuration software:
SyCon
800 mA
140NOA62200
(generation 4)
6/77
I
nter
B
®
us bus
Asynchronous serial
links
2 non-isolated RS 232
channels
19.2 kbps
Shielded cable
- Reading/writing of ASCII
sequences, 7 or 8 bits,
controlled by PLC
application program
- Application of message
formats to character
strings
- Integrated command
interpreter
ProWORX,
Concept, and
Unity Pro CPUs
Unity Pro
Concept V2.2 (min.)
ProWORX 32
300 mA
140ESI06210
6/81
6/3
0
0
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for 990XCP98000