990XCP98000 SQUARE D, 990XCP98000 Datasheet - Page 47

no-image

990XCP98000

Manufacturer Part Number
990XCP98000
Description
QUANTUM CPU BATTERY FOR S
Manufacturer
SQUARE D
Datasheet

Specifications of 990XCP98000

Rohs Compliant
YES
Battery Capacity
1800mAh
Battery Technology
Lithium
Battery Voltage
3V
Battery Terminals
Connector
Weight
0.12lb
Characteristics
Functional safety certification
Approvals
Number of outputs
Number of groups
Number of outputs per group
Input logic
LEDs
I/O addresses
Voltages
Residual voltage
Leakage current
Max. load current
Maximum peak current
Response time
(on resistive loads)
Output protection (internal)
Maximum load
Dielectric strength
Diagnostics
Bus current required
Dissipated power
External power supply
Fuses
Characteristics (continued)
Safety DC output module
Module type
Limit values
Maximum values
Per point
Per module
Per point
Off-to-on
On-to-off
Inductance
Capacity
On filament lamp
Between groups
Between output and bus
Between groups and bus
Internal
External
(continued)
Per group
Per group
Per point
V c
V c
V c
mA
A
A
A
ms
ms
Henry
µF
W
V rms
V rms
V rms
mA
W
V
c
Modicon
automation platform
Safety discrete I/O modules
DC output module
(1) It is mandatory to use a sensor power supply that does not reset automatically after breaking,
(2) There is only one group of 16 channels at the wiring terminals.
140 SDO 953 00S
Certified by TÜV Rheinland as suitable for use in an SIL2 level safety function
e, UL, CSA, CSA Hazardous Location
16
1
16
Positive
Active 1…16 (green) - indicates the point status
F 1…16 (red) - indicates channel inoperable
4 output words and 7 input words
19.2 …30
34
y 0.3 to 0.5 A
0.5 at 30 V c per deactivated point
0.65
10.4
2 for 10 ms, once
y 20
y 20
- Elimination of transient voltage (internal)
- Overload
- Breaking (0.7 A at 10 ms)
- Current limit (2 A)
0.5 at 8 Hz switching frequency
L = 1/I
1500 a for 1 minute
- Overload
- System inoperable
- Process power supply is inoperative
- Channel inoperative (impulse test, channel opening < 1 ms)
350
1.9 + 0.65 I
19.2…30 always with manual reset (1) (2)
Mandatory, fast-blow, 10 A max, dependent on the module load current
type 24 V c 10 A: ABL8 RPS 24100 in manual mode.
There is only one group of 16 outputs. The 24 V commons, as well as the 0 V commons, are
connected internally. For reasons of safety, it is advisable to connect at least 2 ground lines
(0 V common) to the wiring terminals.
2
.F where L: load inductance (Henry). I: load current (A). F: switching frequency (Hz)
2
(I total module load current)
®
Quantum
1/39
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for 990XCP98000