990XCP98000 SQUARE D, 990XCP98000 Datasheet - Page 333

no-image

990XCP98000

Manufacturer Part Number
990XCP98000
Description
QUANTUM CPU BATTERY FOR S
Manufacturer
SQUARE D
Datasheet

Specifications of 990XCP98000

Rohs Compliant
YES
Battery Capacity
1800mAh
Battery Technology
Lithium
Battery Voltage
3V
Battery Terminals
Connector
Weight
0.12lb
Functions
(continued)
Modicon
automation platform
Unity Pro
Unity Pro XLS provides the option of performing an auto-test to verify that the
software components installed have not been corrupted, for example, due to a hard
disk failure. This auto-test is based on a CRC calculation.
Unity Pro XLS checks the version and CRC:
v
v
v
Unity Pro XLS auto-tests are performed upon request by the user, for example:
v
v
v
PLC
With Unity Pro XLS, every binary file generated for a safety project features a version
management field that provides the date and time when it was generated.
This information is useful for checking the project.
It is possible to download a safety project from the PLC to Unity Pro XLS under the
following conditions:
v
v
SIL-rated Quantum PLC.
v
download.
The unrestricted memory area contains bits and words that are not protected against
write operations from external equipment such as HMI terminals, PLCs, etc.
v
v
v
in conjunction with specific function blocks: S_MOVE_BIT and S_MOVE_WORD.
In the edit phase first and then in the generation phase, Unity Pro XLS checks to
make sure than only data from the unrestricted memory area are used at the input of
the function blocks S_MOVE_BIT and S_MOVE_WORD.
Unity Pro XLS provides a useful list of cross references, allowing easy identification
of the way variables are used and verification of the application of this rule.
Note: For safety applications, it is common practice to verify the correct transfer of data by writing
Unity Pro XLS
Distinctive features and specific procedures
Auto-testing software tools
Time-stamping binary files
Downloading a project to Unity Pro XLS
Unrestricted memory
Of its DLLs
Of the library database of the safety FFB
Of the catalog database of hardware products
After installing or uninstalling any program on the computer
Before loading the final application program onto the SIL-rated Quantum PLC
Before modifying the application program executed on the SIL-rated Quantum
This must have been defined as an option for the safety project.
The user must know the application password to establish a connection to the
The SIL-rated Quantum PLC must be placed in maintenance mode to perform the
It is located at the beginning of the memory.
Its size can be configured with Unity Pro XLS.
Values cannot be used directly in the unrestricted memory area and can only be used
the data twice (to different variables) and then comparing them.
XLS software
(continued)
®
Quantum
7/33
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9