QDE-825D BANNER ENGINEERING, QDE-825D Datasheet - Page 6

Safety Light Curtain

QDE-825D

Manufacturer Part Number
QDE-825D
Description
Safety Light Curtain
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of QDE-825D

Light Curtain Type
Safety
Accessory Type
Machine Interface Cable
For Use With
EZ-Screen Safety Light Screen
4
4
Reduced Resolution increases the minimum diameter of an
object that the light screen can reliably detect anywhere within
its defined area. Reduced Resolution is generally used to allow
one or more objects (usually workpiece materials) to move
through the defined area, at any point, without tripping the
OSSD safety outputs.
Selecting two-beam Reduced Resolution will reduce the overall
minimum object sensitivity, which allows multiple objects to
move through the defined area (see Section 3.4.2). The effect
is that every two consecutive beams (except for the sync beam)
can be blocked, but not cause the OSSDs to turn OFF. This is
also called “Multiple-Point Floating Blanking.”
Figure 1-2. Reduced Resolution
Figure 1-3. EZ-SCREEN emitter and receiver status indicators
P/N 133487
P/N 112852 rev. F
1.4.6 Reduced Resolution (Floating Blanking)
status of approx.
Zone Indicators
1/8 of the total
(each shows
Overview
Overview
beams)
Receiver
Press Break
Die
Zone 1 Indicator
(indicates beam synchronization status)
Defined Area
Beams of
Workpiece
3-digit
Diagnostic
Display
Yellow Reset
Indicator
Status Indicator
(Red/Green)
Resolution directly affects the minimum allowable distance
between the defined area of a light screen and the nearest
hazard point (separation distance, see Section 3.1.1). The
green status indicator on the receiver flashes when Reduced
Resolution is enabled. The ignored object size and resultant
Reduced Resolution are listed in Section 3.4.2.
Status indicators on both the emitter and receiver are clearly
visible on each sensor’s front panel.
• Emitter:
• Receiver:
See Sections 4.4 and 5.1 for more information about specific
indicator and Diagnostic Display code meanings.
1.4.7 Status Indicators
Bi-color red/green Status indicator – shows whether power is
applied, and whether the emitter is in RUN mode, TEST mode,
or Lockout condition.
1-Digit Diagnostic Display – indicates specific error or
configuration conditions.
Bi-color red/green Zone indicators – show status of a group of
beams:
- aligned and clear (green ON), or
- blocked and/or misaligned (red ON), or
- fixed blanked area (flashing green).
Yellow Reset indicator – shows System status:
- RUN mode (ON) or
- waiting for a reset (flashing).
Bi-color red/green Status indicator – shows System status:
- Reduced Resolution enabled (flashing green),
- outputs are ON or OFF (green ON or red ON), or
- the System is in Lockout condition (flashing red).
3-Digit Diagnostic Display – indicates specific error,
configuration conditions, or total number of blocked beams.
Emitter
Banner Engineering Corp.
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
www.bannerengineering.com • Tel: 763.544.3164
Instruction Manual
Minneapolis, U.S.A.
Minneapolis, U.S.A.
EZ-SCREEN
Status Indicator
(Red/Green)
1-digit
Diagnostic
Display

Related parts for QDE-825D