NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 321
NT30-KBA01
Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Specifications of NT30-KBA01
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
- Current page: 321 of 466
- Download datasheet (3Mb)
Setting
Operation
Changing Numerals/Character Strings by Copying the Contents by Operation at the
PT Status Control Area
312
Changing Numeral and Character String Display
PT
A
Reference:
Memory table
S If the Words settings differ between the memory tables (copy source and copy
S When the PT is set to NT30/620 compatible mode, copying between memory
If this method is used, contents can be copied between any required memory
tables at any time in response to a command from the host. Note that this meth-
od is possible only for the following combinations.
• Numeral memory table → Numeral memory table
• Character string memory table → Character string memory table
The PT status control area must be allocated to a word in the host, accordingly,
no special settings are required for copying the data between memory tables.
The following areas are provided in the PT status control area to be used for
copying the data between memory tables.
• 2nd word from the beginning of the area (word n + 1)
• 3rd word from the beginning of the area (word n + 2)
• 4th word from the beginning of the area (word n + 3)
(n: Beginning word number of the PT status control area)
Word
destination tables), numerals or character strings are copied correctly since 2
words are secured for a numeral memory table and 20 words for a character
string memory table in the PT. If the memory table is allocated to a word in the
host, however, copying may not be executed correctly if the Words settings
differ between the memory tables (copy source and copy destination tables).
tables is performed differently. Refer to Appendix C for details on the NT30/620
compatible mode.
n
n+1
n+2
n+3
n+4
Copy source memory table No.
Copy destination memory table No.
Memory table type (bit 2) and PT status control bit that instructs the execution
of copying (bit 3)
A
A
Copy source
Copy destination
(for display)
15
Copy destination memory table No. (4-digit BCD or hexadecimal)
14 13 12 11 10 9
Copy source memory table No. (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
PC
Screen switch setting
Copy memory
table setting
PT status control setting
Reserved for system use
PT status control area
Reserved for system use
PT status control bits
The configuration and functions of these words are
different when the PT is in NT30/620 compatible mode.
8
7
6
5
4
← Copy source memory table No.
← Copy destination memory table No.
← Copy execution command
3
2
1
0
Bit
Screen switch setting
Copy memory
table setting
PT status control
Section
3-5
Related parts for NT30-KBA01
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
ANTI GLARE COVER FOR NT31
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: