NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 36

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
PT Status Control Area
(PC ↔ PT)
PT Status Notify Area
(PT to PC)
Functions of the Window
Control Area
(PC to and from PT)
Communications with the Host
Reference: When the PT is set to NT30/620 compatible mode, the word configuration is iden-
tical to that of the earlier NT30, NT30C, NT620S, NT620C, and NT625C PTs.
The PC bit allocated to bit memory table for which the history property has been
set is continually monitored: when the bit comes ON (1), the time and the number
of times, and the contents of the character string memory table registered for the
bit memory table, are recorded in the alarm history record data.
This record data can be displayed as the alarm history.
The PT status control area is used to control the PT status. When data is written
to this area in the PC, the PT reads the contents and operates according to the
contents.
Example of PT Status Control Area Application
When data is written to the PT status control area, the PT operates as shown
below (page 46).
The PT status notify area is used to notify the changes in the PT status.
When the PT status changes, the change is written to this area in the PC. By
reading the data from this area, the PT status can be checked.
Example of PT Status Notify Area Application
When the PT status changes, the change is applied to the PT status notify area
as shown below (page 55).
The window control area is used to notify and control the window status. The
window control area has areas that correspond to three windows. Each area
stores the screen number, and the X and Y coordinates of the lower left corner of
the window that is being displayed.
When data is written to this area in the PC, the PT reads the contents and exe-
cutes tasks such as switching the windows to be displayed or moving the posi-
tion of the windows according to the contents (page 232).
When the window display status changes, the change is written to this area in
the PC. By reading the data from this area, the window display status can be
checked (refer to page 232).
If the window functions are not used, it is not necessary to allocate a window con-
trol area to the host.
Continuous
buzzer
sound
Copy
12345678
Numeral memory table 50
Numeral memory table 7
Screen 3 display
PT
PT
7 8 9
4 5 6
1 2 3
0 .
Numeral memory table 13
1 2 3 4 5 6 7 8
12345678
Allocated word (numeral table 13)
PC
PT status notify area
5
1
8800
PT status control area
0013
PC
6
2
7
3
0003
0050
1007
A000
8
4
Content upgrade memory table
PT status
Start
Start + 1
Section
Screen switch setting
Memory table
Copy setting
PT status control bits
System reserve
1-4
27

Related parts for NT30-KBA01