62
Areas for Control/Notification
When The Screen is Switched to System Screen, Error Screen Or System
Menu, While The Window is Being Displayed.
The behavior depends on the screen type as follows. (Even when the global win-
dow and local window were displayed before screen switching, the each screen
also behaves as the table below. )
If a standard screen or an overlapping screen is displayed again, the same glob-
al window will be opened at the same position but the local window will not be
opened.
System screens which close global window are as follows:
• System initializing screen (screen number 9000)
• Programming Console function screen (screen number 9020)
• Device Monitor function screen (screen number 9021, 9022, or 9023)
With Occurrence history screen (screen number 9001) and frequency history
screen (screen number 9002) global window remains opened.
Data is written to the window control area from both the PT and the host. The
meaning of the data differs according to whether it is written from the PT or the
host.
When The Data is Written From The Host
To switch, open, close or move a window on the PT by an instruction from the
host, write the window screen number or coordinates to the window No.. X coor-
dinate or Y coordinate as 4-digits BCD or hexadecimal. Whether the values are
BCD or hexadecimal is determined by the setting for numeral storage type in the
PT configuration settings made with the Support Tool.
By changing the screen No.. window can be switched, opened or closed.
It is possible to move the window position by changing the X coordinate and Y
coordinate.
Global window
Local window
Global window
Local window
* If the local window open attribute is set for the screen switched to, the local
Window type
Window type
window opens.
(Window screen No.125)
Botom left coordinate (60, 179)
Local Window1 opens
PT
Screen No.
Screen No.
Retains the existing value
Retains the existing value
Cleared to 0
Cleared to 0
X coordi-
X coordi-
nate
nate
PC
Window control area
X coordinate
Y coordinate
Screen No.
Y coordi-
Y coordi-
nate
nate
← 0125
← 0060
← 0179
Remain opened
Closed (*)
Closed
Closed
Section
Local Window1
Status
Status
2-2