NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 55

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2-2
2-2-1 PT Status Control Area (Host ↔ PT)
46
Areas for Control/Notification
Areas for Control/Notification
Reference:
Word
n
n + 1
n + 2
n + 3
n + 4
Reference: The configuration and functions of the PT status control area are different when
15 14 13 12 11 10 9
S The PT status control area and PT status notify area must be allocated to the
S The PT status control area, PT status notify area and window control area must
S When multiple PTs are connected to one PC, the PT status control area, PT
S Allocate window control area to the host only when the window is used and
the PT is set to NT30/620 compatible mode. Refer to Appendix C for details on
the NT30/620 compatible mode.
The following areas are provided for PT control and PT status notification be-
tween the PT and the host.
• PT status control area
• PT status notify area
• Window control area
When data is written to this area from the host, the PT reads the data and oper-
ates accordingly. However, note that the number of the currently displayed
screen is written to the screen switch setting word from the PT too.
The PT status control area is configured as five consecutive words as shown
below. The first word (word n) is set in the Control/Notify Area settings in the PT
configuration settings made with the Support Tool.
Screen No. (4-digit BCD or hexadecimal)
host. Screen data cannot be downloaded from the Support Tool unless they
have been allocated.
be set so that they do not overlap.
status notify area and window control area of each PT must be set so that they
do not overlap, or the movement of PT will be unstable.
when the window is controlled from the host. Even if the window control area is
not allocated to the host, a window can be controlled by touch switch operation
etc.
This area is used to designate the screen to be displayed at the PT, to copy
data contents between memory tables in the PT, and to control the status of the
backlight and other statuses.
This area is used to notify the memory table number to the host when there is a
change in the data contents of a memory table in the PT, and to notify informa-
tion such as changes in the PT status.
This area is used to designate the window screen number or display position
from the host, and to notify these information from PT.
No. (4-digit BCD or hexadecimal)
Copy source memory table No.
Copy destination memory table
(4-digit BCD or hexadecimal)
Reserved for system use
PT status control bits
8
7
6
5
4
3
2
1
0
Bit
Screen switch setting
Copy memory table
setting
PT status control
Section
2-2