CS1D-II102D Omron, CS1D-II102D Datasheet - Page 317

no-image

CS1D-II102D

Manufacturer Part Number
CS1D-II102D
Description
CS1D Dual IO Interface Unit
Manufacturer
Omron
Datasheet

Specifications of CS1D-II102D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CPU Standby Information
Unit Online Replacement Information
282
Auxiliary Area
I/O Unconfirmed Error Flag
Online Replacement Flag
Duplex Communications Unit
Error Flag
Duplex Communications Unit
Verification Error Flag
CPU Bus/Special I/O Unit
Startup Flag
Duplex Bus Error Standby
Flag (Duplex CPU Systems
only)
Duplex Verification Error
Standby Flag (Duplex CPU
Systems only)
Waiting for Other CPU Unit
Standby Flag (Duplex CPU
Systems only)
Inner Board Startup Flag
(Duplex CPU Systems only)
Expansion Power OFF
Standby Flag
Online Replacement Flag
I/O Table Creation Error Flag
Online Replacement Slot
Flags
Name
Name
Name
A26109
A26110
A26111
A26112
A32203
A32204
A32205
A32206
A32207
A32208
A03115
A26110
A034 to
A041
Address
Address
Address
ON: I/O detection has not been completed.
Turns OFF when I/O tables are generated normally.
ON: An online replacement operation is being performed (It
is treated as an I/O table creation error.) This flag will be
turned OFF automatically when the online replacement
operation has been completed. (Do not attempt to create the
I/O tables while this flag is ON.) (See Unit Online Replace-
ment Information below.)
ON: Duplex Units are not mounted for a unit number speci-
fied for Duplex Communications Units (i.e., one Unit is miss-
ing or the mounted Units do not support duplex operation).
ON: The duplex setting in the PLC Setup for a unit number
specified for Duplex Communications Units does not agree
with the setting on the Duplex Communications Units. The
I/O tables will not be created and an I/O Table Creation Error
will occur. Refer to the Operation Manual for the Communi-
cations Units for details on Unit settings.
ON: The CPU Unit is on standby waiting for CPU Bus or
Special I/O Units to start.
ON: The CPU Unit is on standby because a duplex bus error
occurred at startup.
ON: The CPU Unit is on standby because a duplex verifica-
tion error occurred at startup.
ON: The CPU Unit is on standby waiting for the other CPU
Unit to start operation at startup.
ON: The CPU Unit is on standby waiting for an Inner Board
to start.
ON: The CPU Unit is on standby because power is not being
supplied to an Expansion Rack.
ON: A Basic I/O Unit, Special I/O Unit, or CPU Bus Unit is
being replaced online on the CPU Rack, an Expansion
Rack, or a Long-distance Expansion Rack. (See note 3.)
ON: User attempted to generate the I/O table during online
replacement, causing an I/O table creation error. (See note
3.) (Do not attempt to create an I/O table while a Basic I/O
Unit, Special I/O Unit, or CPU Bus Unit is being replaced
online, i.e., while one of the Online Replacement Slot Flags
in A034 to A041 is ON.)
ON: Online replacement is being performed (see note 3) for
the slot that corresponds to the ON bit.
A03400 to A03404: CPU Rack slots 0 to 4
A03405 to A03407: CPU Rack slots 5 to 7
A03415:
A03500 to A03508: Expansion Rack 1, slots 0 to 8
A03600 to A03608: Expansion Rack 2, slots 0 to 8
A04100 to A04108: Expansion Rack 7, slots 0 to 8
(Single CPU Systems only)
Duplex Unit
...
Description
Description
Description
Section 8-11
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Access
Access
Access

Related parts for CS1D-II102D