CS1D-II102D Omron, CS1D-II102D Datasheet - Page 534
CS1D-II102D
Manufacturer Part Number
CS1D-II102D
Description
CS1D Dual IO Interface Unit
Manufacturer
Omron
Datasheet
1.CS1D-SP002.pdf
(638 pages)
Specifications of CS1D-II102D
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 534 of 638
- Download datasheet (12Mb)
Load Short-circuit Protection
CS1W-OD212/OD232/OD262/MD262
As shown below, normally when the output bit turns ON (OUT), the transistor will turn ON and then output cur-
rent (Iout) will flow. If the output (Iout) is overloaded or short-circuited exceeding the detection current (Ilim), the
output current (Iout) will be limited as shown in Figure 2 below. When the junction temperature (Tj) of the output
transistor reaches the thermal shutdown temperature (Tstd), the output will turn OFF to protect the transistor
from being damaged, and the alarm output bit will turn ON to light the ERR indicator. When the junction tem-
perature (Tj) of the transistor drops down to the reset temperature (Tr), the ERR indicator will be automatically
reset and the output current will start flowing.
Figure 1: Normal Condition
Figure 2: Overload or Short-circuit
Operating Restrictions for the CS1W-OD212/OD232/OD262/MD262
Although the CS1W-OD212/OD232/OD262/MD262 are provided with short-circuit protection, these are for pro-
tecting internal circuits against momentary short-circuiting in the load. As shown in Figure 2 below, the short-
circuit protection is automatically released when the Tj equals to Tr. Therefore, unless the cause of short-circuit
is removed, ON/OFF operations will be repeated in the output. Leaving short-circuits for any length of time will
cause internal temperature rise, deterioration of elements, discoloration of the case or PCBs, etc. Therefore,
observe the following restrictions.
Restrictions
If a short-circuit occurs in an external load, immediately turn OFF the corresponding output and remove the
cause. The CS1W-OD212/OD232/OD262/MD262 turn ON an alarm output bit that corresponds to the external
load output number. There is an alarm output bit for every common.
When an alarm output bit turns ON, use a self-holding bit for the alarm in the user program and turn OFF the
corresponding output.
The alarm output bit is allocated in the Basic I/O Unit Information Area (A050 to A089) for every Unit mounting
slot.
The following table shows the correspondence between output bits and bits in the Basic I/O Unit Information
Area.
Specifications of Basic I/O Units and High-density I/O Units
CS1W-OD212
OUT
I
ERR
OUT
ON
OFF
ON
OFF
ON
OFF
Output bit
Mounted in even slot
Mounted in odd slot
OUT
I
ERR
OUT
ON
OFF
ON
OFF
ON
OFF
I
lim
0
8
0 to 7
OUT: OUTPUT instruction
I
ERR: Alarm output, ERR indicator
I
Tj:
Tstd: Thermal shutdown temperature
Tr:
Tj =Tstd Tj =Tr
OUT
lim
m
:
: Output current
1
9
8 to 15
Detection current
Junction temperature of transistor
Reset temperature
---
---
0 to 15
m+1
---
---
0 to 15
m+2
---
---
Appendix A
0 to 15
m+3
499
Related parts for CS1D-II102D
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
CS1D Dual IO Control Unit
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CS1D Dual CPU Exp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CS1D Dual Exp Rack
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CS1D Dual IO Exp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: