CS1D-II102D Omron, CS1D-II102D Datasheet - Page 337

no-image

CS1D-II102D

Manufacturer Part Number
CS1D-II102D
Description
CS1D Dual IO Interface Unit
Manufacturer
Omron
Datasheet

Specifications of CS1D-II102D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
302
Auxiliary Area
Explicit Communications Error
Flag
Network Communications
Error Flag
Network Communications
Response Code
Peripheral Port Communica-
tions Error Flag
Peripheral Port Restart Bit
Peripheral Port Settings
Change Bit
Peripheral Port Error Flags
Peripheral Port PT Communi-
cations Flags
Peripheral Port PT Priority
Registered Flags
Information on Explicit Message Instructions (Single CPU Systems Only)
Peripheral Port Communications Information
Name
Name
A21300 to
A21307
A21900 to
A21907
A203 to
A210
A39212
A52601
A61901
A52808 to
A52815
A39400 to
A39407
A39408 to
A39415
Address
Address
Turn ON when an error occurs in executing an Explicit Mes-
sage Instruction (EXPLT, EGATR, ESATR, ECHRD, or
ECHWR).
Bits 00 to 07 correspond to communications ports 0 to 7.
The corresponding bit will turn ON both when the explicit
message cannot be sent and when an error response is
returned for the explicit message.
The status will be maintained until the next explicit message
communication is executed. The bit will always turn OFF
when the next Explicit Message Instruction is executed.
Turn ON if the explicit message cannot be sent when execut-
ing an Explicit Message Instruction (EXPLT, EGATR,
ESATR, ECHRD, or ECHWR).
Bits 00 to 07 correspond to communications ports 0 to 7.
The corresponding bit will turn ON when the explicit mes-
sage cannot be sent.
The status will be maintained until the next explicit message
communication is executed. The bit will always turn OFF
when the next Explicit Message Instruction is executed.
The following codes will be stored when an Explicit Message
Instruction (EXPLT, EGATR, ESATR, ECHRD, or ECHWR)
has been executed.
A203 to A210 correspond to communications ports 0 to 7.
If the Explicit Communications Error Flag turns OFF, 0000
hex is stored.
If the Explicit Communications Error Flag is ON and the Net-
work Communications Error Flag is ON, the FINS end code
is stored.
If the Explicit Communications Error Flag is ON and the Net-
work Communications Error Flag is OFF, the explicit mes-
sage end code is stored.
During communications, 0000 hex will be stored and the
suitable code will be stored when execution has been com-
pleted. The code will be cleared when operation is started.
ON when a communications error has occurred at the
peripheral port.
Turn this bit ON to restart the peripheral port.
ON while the peripheral port’s communications settings are
being changed.
These flags indicate what kind of error has occurred at the
peripheral port.
The corresponding bit will be ON when the peripheral port is
communicating with a PT in NT link mode. Bits 0 to 7 corre-
spond to units 0 to 7.
The corresponding bit will be ON for the PT that has priority
when the peripheral port is communicating in NT link mode.
Bits 0 to 7 correspond to units 0 to 7.
Description
Description
Section 8-11
Read-only
Read-only
Read-only
Read-only
Read/write
Read/write
Read/write
Read-only
Read-only
Access
Access