LPC47N227TQFP Standard Microsystems (SMSC), LPC47N227TQFP Datasheet - Page 107

no-image

LPC47N227TQFP

Manufacturer Part Number
LPC47N227TQFP
Description
Manufacturer
Standard Microsystems (SMSC)
Datasheet

Specifications of LPC47N227TQFP

Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC47N227TQFP
Manufacturer:
RFT
Quantity:
386
Part Number:
LPC47N227TQFP
Manufacturer:
SMSC
Quantity:
1 000
Part Number:
LPC47N227TQFP
Manufacturer:
SMSC
Quantity:
20 000
Programmed I/O Mode or Non-DMA Mode
The ECP or parallel port FIFOs may also be operated using interrupt driven programmed I/O. Software
can determine the writeIntrThreshold, readIntrThreshold, and FIFO depth by accessing the FIFO in Test
Mode.
Programmed I/O transfers are to the ecpDFifo at 400H and ecpAFifo at 000H or from the ecpDFifo located
at 400H, or to/from the tFifo at 400H. To use the programmed I/O transfers, the host first sets up the
direction and state, sets dmaEn to 0 and serviceIntr to 0.
The ECP requests programmed I/O transfers from the host by activating the interrupt. The programmed
I/O will empty or fill the FIFO using the appropriate direction and mode.
Note: A threshold of 16 is equivalent to a threshold of 15. These two cases are treated the same.
Programmed I/O - Transfers from the FIFO to the Host
In the reverse direction an interrupt occurs when serviceIntr is 0 and readIntrThreshold bytes are available
in the FIFO. If at this time the FIFO is full it can be emptied completely in a single burst, otherwise
readIntrThreshold bytes may be read from the FIFO in a single burst.
readIntrThreshold =(16-<threshold>) data bytes in FIFO
An interrupt is generated when serviceIntr is 0 and the number of bytes in the FIFO is greater than or
equal to (16-<threshold>). (If the threshold = 12, then the interrupt is set whenever there are 4-16 bytes in
the FIFO). The host must respond to the request by reading data from the FIFO. This process is
repeated until the last byte is transferred out of the FIFO. If at this time the FIFO is full, it can be
completely emptied in a single burst, otherwise a minimum of (16-<threshold>) bytes may be read from
the FIFO in a single burst.
Programmed I/O - Transfers from the Host to the FIFO
In the forward direction an interrupt occurs when serviceIntr is 0 and there are writeIntrThreshold or more
bytes free in the FIFO. At this time if the FIFO is empty it can be filled with a single burst before the empty
bit needs to be re-read. Otherwise it may be filled with writeIntrThreshold bytes.
writeIntrThreshold =
(16-<threshold>) free bytes in FIFO
An interrupt is generated when serviceIntr is 0 and the number of bytes in the FIFO is less than or equal to
<threshold>. (If the threshold = 12, then the interrupt is set whenever there are 12 or less bytes of data in
the FIFO.) The host must respond to the request by writing data to the FIFO. If at this time the FIFO is
empty, it can be completely filled in a single burst, otherwise a minimum of (16-<threshold>) bytes may be
written to the FIFO in a single burst. This process is repeated until the last byte is transferred into the
FIFO.
Parallel Port Floppy Disk Controller
The Floppy Disk Control signals are available optionally on the parallel port pins. When this mode is
selected, the parallel port is not available. There are two modes of operation, PPFD1 and PPFD2.
These modes can be selected in the Parallel and Serial Extended Setup Register (CR04). PPFD1 has
only drive 1 on the parallel port pins; PPFD2 has drive 0 and 1 on the parallel port pins. See the
Configuration section for description of the register. The FDC_PP pin can be used to switch the
parallel port pins between the FDC and the parallel port functions. See the following sub-section.
The following parallel port pins are read as follows by a read of the parallel port register:
1. Data Register (read) = last Data Register (write)
107