EP3C5F256C8N Altera, EP3C5F256C8N Datasheet - Page 95

IC CYCLONE III FPGA 5K 256-FBGA

EP3C5F256C8N

Manufacturer Part Number
EP3C5F256C8N
Description
IC CYCLONE III FPGA 5K 256-FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C5F256C8N

Number Of Logic Elements/cells
5136
Number Of Labs/clbs
321
Total Ram Bits
423936
Number Of I /o
182
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
256-FBGA
No. Of Logic Blocks
321
Family Type
Cyclone III
No. Of I/o's
182
I/o Supply Voltage
3.3V
Operating Frequency Max
402MHz
Operating Temperature Range
0°C To +85°C
Rohs Compliant
Yes
For Use With
544-2601 - KIT DEV CYCLONE III LS EP3CLS200544-2411 - KIT DEV NIOS II CYCLONE III ED.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-2423
EP3C5F256C8N

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C5F256C8N
Manufacturer:
ALTERA
Quantity:
853
Part Number:
EP3C5F256C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C5F256C8N
Manufacturer:
ALTERA
0
Part Number:
EP3C5F256C8N
Manufacturer:
ALTERA
Quantity:
10
Part Number:
EP3C5F256C8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP3C5F256C8N
0
Chapter 5: Clock Networks and PLLs in the Cyclone III Device Family
PLL Reconfiguration
© December 2009
Altera Corporation
Table 5–10
PHASECOUNTERSELECT setting.
Table 5–10. Phase Counter Select Mapping
To perform one dynamic phase shift step, you must perform the following
procedures:
1. Set phaseupdown and phasecounterselect as required.
2. Assert phasestep for at least two scanclk cycles. Each phasestep pulse
3. Deassert phasestep.
4. Wait for phasedone to go high.
5. You can repeat steps
All signals are synchronous to scanclk, so they are latched on the scanclk edges
and must meet t
Figure 5–24. PLL Dynamic Phase Shift
Dynamic phase shifting can be repeated indefinitely. All signals are synchronous to
scanclk, so they must meet t
enables one phase shift.
shifts.
PHASECOUNTERSELECT [2]
phasecounterselect
lists the PLL counter selection based on the corresponding
phaseupdown
0
0
0
0
1
1
1
SU
phasestep
phasedone
or t
scanclk
H
requirements (with respect to the scanclk edges).
1
through
SU
or t
4
H
as many times as required to get multiple phase
[1]
0
0
1
1
0
0
1
requirements (with respect to scanclk edges).
[0]
0
1
0
1
0
1
0
Cyclone III Device Handbook, Volume 1
All Output Counters
C0 Counter
C1 Counter
C2 Counter
C3 Counter
C4 Counter
M Counter
Selects
5–31