PEB20256E-V21 Infineon Technologies, PEB20256E-V21 Datasheet - Page 67

IC CONTROLLER INTERFACE 388-BGA

PEB20256E-V21

Manufacturer Part Number
PEB20256E-V21
Description
IC CONTROLLER INTERFACE 388-BGA
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20256E-V21

Function
Multichannel Network Interface Controller (MUNICH)
Interface
HDLC, PPP, Serial, TMA
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
200mA
Power (watts)
3W
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
388-BBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Circuits
-
Other names
PEB20256E-V21
PEB20256E-V21IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB20256E-V21
Manufacturer:
MAX
Quantity:
63
Part Number:
PEB20256E-V21
Manufacturer:
Infineon Technologies
Quantity:
10 000
descriptor to the next transmit descriptor. Therefore all information in the next descriptor
must be valid when the data management unit branches to a descriptor. The last
DWORD of a transmit descriptor optionally is written by the MUNICH256 when
processing of a descriptor has finished.
Table 4-3
FE
HOLD
Data Sheet
DWORD
DWORD
ADDR.
ADDR.
0C
0C
00
04
08
00
04
08
H
H
H
H
H
H
H
H
FE HOLD THI CEN
31
15
0
0
Transmit Descriptor Structure
Frame end
It indicates that the current transmit data section (addressed by transmit
data pointer) contains the end of a frame. After the last byte is read from
system memory this bit is passed to the transmit buffer and to the
protocol machine. The bit FE informs the transmit buffer to move a
stored frame to the protocol machine even if the programmed transmit
forward threshold is not reached (see
Page 7 4
(HDLC, PPP) and then to send the interframe time-fill. Providing a
transmit descriptor with FE = ’0’ and HOLD = ’1’ is an error.
Hold indication
It indicates that this descriptor is the last valid element of a linked list.
0
1
30
14
C
0
29
13
0
0
Next descriptor is available in the shared memory. The data
management unit branches to the next descriptor as soon as
processing of the current descriptor has finished.
The current descriptor is the last descriptor containing valid data
in the data section. As soon as the data management unit has
transferred the data contained in the data section to the internal
buffer, it tries one more time to read the descriptor. In case that
). The protocol machine is informed to append the checksum
28
12
0
0
NextTransmitDescriptorPointer(31:2)
27
11
0
0
0
NextTransmitDescriptorPointer(31:2)
26
10
0
0
0
TransmitDataPointer(31:0)
TransmitDataPointer(31:0)
25
0
0
9
0
67
NO(15:0)
24
0
0
8
0
23
0
0
7
0
22
0
0
6
0
“Internal Transmit Buffer” on
21
0
5
0
Functional Description
20
0
4
0
DescriptorID(5:0)
19
0
3
0
PEB 20256 E
PEF 20256 E
18
0
2
0
17
0
1
0
0
04.2001
16
0
0
0
0

Related parts for PEB20256E-V21