AT32UC3C1256C Atmel Corporation, AT32UC3C1256C Datasheet - Page 573

no-image

AT32UC3C1256C

Manufacturer Part Number
AT32UC3C1256C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT32UC3C1256C

Flash (kbytes)
256 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
81
Ext Interrupts
100
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
7
Twi (i2c)
3
Uart
5
Can
2
Lin
5
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
4
Dac Resolution (bits)
12
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
68
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6 or 4.5 to 5.5
Operating Voltage (vcc)
3.0 to 3.6 or 4.5 to 5.5
Fpu
Yes
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
22
Input Capture Channels
12
Pwm Channels
19
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3C1256C-AUR
Manufacturer:
LORLIN
Quantity:
1 000
Part Number:
AT32UC3C1256C-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C1256C-AUT
Manufacturer:
ATMEL
Quantity:
1 001
Part Number:
AT32UC3C1256C-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C1256C-AZR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C1256C-AZT
Manufacturer:
Atmel
Quantity:
10 000
25.6.3.2
32117C–AVR-08/11
Manchester Encoder
encoded based on biphase Manchester II format. To enable this mode, set the MAN field in the
MR register to 1. Depending on polarity configuration, a logic level (zero or one), is transmitted
as a coded signal one-to-zero or zero-to-one. Thus, a transition always occurs at the midpoint of
When the Manchester encoder is in use, characters transmitted through the USART are
each bit time. It consumes more bandwidth than the original NRZ signal (2x) but the receiver has
more error control since the expected input must show a change at the center of a bit cell. An
example of Manchester encoded sequence is: the byte 0xB1 or 10110001 encodes to 10 01 10
10 01 01 01 10, assuming the default polarity of the encoder.
scheme.
Figure 25-7. NRZ to Manchester Encoding
The Manchester encoded character can also be encapsulated by adding both a configurable
preamble and a start frame delimiter pattern. Depending on the configuration, the preamble is a
training sequence, composed of a pre-defined pattern with a programmable length from 1 to 15
bit times. If the preamble length is set to 0, the preamble waveform is not generated prior to any
character. The preamble pattern is chosen among the following sequences: ALL_ONE,
ALL_ZERO, ONE_ZERO or ZERO_ONE, writing the field TX_PP in the MAN register, the field
TX_PL is used to configure the preamble length.
patterns. To improve flexibility, the encoding scheme can be configured using the TX_MPOL
field in the MAN register. If the TX_MPOL field is set to zero (default), a logic zero is encoded
with a zero-to-one transition and a logic one is encoded with a one-to-zero transition. If the
TX_MPOL field is set to one, a logic one is encoded with a one-to-zero transition and a logic
zero is encoded with a zero-to-one transition.
Manchester
encoded
encoded
NRZ
data
data
Txd
1
0
1
1
Figure 25-8
0
Figure 25-7
0
illustrates and defines the valid
0
illustrates this coding
AT32UC3C
1
573