SAM3U2E Atmel Corporation, SAM3U2E Datasheet - Page 649

no-image

SAM3U2E

Manufacturer Part Number
SAM3U2E
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U2E

Flash (kbytes)
128 Kbytes
Pin Count
144
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
57
Hardware Qtouch Acquisition
No
Max I/o Pins
96
Ext Interrupts
96
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
5
Twi (i2c)
2
Uart
5
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
33.10.5.3
Figure 33-27. Master Performs a General Call
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
GCACC
SVACC
TXD
General Call
S
GENERAL CALL
GENERAL CALL
0000000 + W
The general call is performed in order to change the address of the slave.
If a GENERAL CALL is detected, GACC is set.
After the detection of General Call, it is up to the programmer to decode the commands which
come afterwards.
In case of a WRITE command, the programmer has to decode the programming sequence and
program a new SADR if the programming sequence matches.
Figure 33-27 on page 649
Note:
This method allows the user to create an own programming sequence by choosing the program-
ming bytes and the number of them. The programming sequence has to be provided to the
master.
WRITE command = 00000100X
A
RESET command = 00000110X
Reset or write DADD
Reset after read
describes the General Call access.
A
DATA1
Programming sequence
New SADR
A
DATA2
A
New SADR
SAM3U Series
SAM3U Series
A
P
649
649

Related parts for SAM3U2E