PM5380-BI PMC-Sierra, Inc., PM5380-BI Datasheet - Page 212

no-image

PM5380-BI

Manufacturer Part Number
PM5380-BI
Description
Network Interface, SATURN User Network Interface (8x155) Telecom Standard Product
Manufacturer
PMC-Sierra, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM5380-BI
Manufacturer:
PMC
Quantity:
648
Part Number:
PM5380-BI
Manufacturer:
PMC
Quantity:
11
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC- 2010299, Issue 2
Register 0x056, 0x156, 0x256, 0x356, 0x456, 0x556, 0x656, 0x756:
BUSY:
RWB:
SPTB Indirect Access Trigger Register
The BUSY bit reports whether a previously initiated indirect read or write to a message
buffer has been completed. BUSY is set to a logic one immediately upon writing to the
SPTB Indirect Address register, and stays high until the initiated access is completed. This
register should be polled to determine when new data is available in the SPTB Indirect Data
register.
The access control bit (RWB) selects between an indirect read or write access to the
selected path trace buffer (receive or transmit as determined by the RRAMACC bit). When
RWB is a logic one, a read access is initiated. The addressed location’s contents are placed
in the SPTB Indirect Data register. When RWB is a logic zero, a write access is initiated.
The data in the SPTB Indirect Data register is written to the addressed location in the
selected buffer.
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R/W
Function
BUSY
RWB
Unused
Unused
Unused
Unused
Unused
Unused
S/UNI®-8x155 ASSP Telecom Standard Product Data Sheet
Default
0
0
X
X
X
X
X
X
Released
212

Related parts for PM5380-BI