PM5380-BI PMC-Sierra, Inc., PM5380-BI Datasheet - Page 229

no-image

PM5380-BI

Manufacturer Part Number
PM5380-BI
Description
Network Interface, SATURN User Network Interface (8x155) Telecom Standard Product
Manufacturer
PMC-Sierra, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM5380-BI
Manufacturer:
PMC
Quantity:
648
Part Number:
PM5380-BI
Manufacturer:
PMC
Quantity:
11
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC- 2010299, Issue 2
Register 0x06A, 0x16A, 0x26A, 0x36A, 0x46A, 0x56A, 0x66A, 0x76A:
HCS[7:0]:
RXCP HCS Error Count
The HCS[7:0] bits indicate the number of HCS error events that occurred during the last
accumulation interval. The contents of these registers are valid a maximum of 40 RCLK
periods after a transfer is triggered by a write to one of RXCP's performance monitor.
The count can also be polled by writing to the S/UNI-8x155 Master Reset and Identity
register (0x000). Writing to register address 0x000 loads all counter registers in all
channels and APS links.
The count can also be polled by writing to the channel Master Interrupt Status register
(offset 0x07). Writing to register offset 0x07 loads all counter registers in the RSOP, RLOP,
RPOP, SPTB, SSTB, RXCP, TXCP, RXFP, and TXFP blocks of the channel.
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R
R
R
R
R
R
R
Function
HCS[7]
HCS[6]
HCS[5]
HCS[4]
HCS[3]
HCS[2]
HCS[1]
HCS[0]
S/UNI®-8x155 ASSP Telecom Standard Product Data Sheet
Default
X
X
X
X
X
X
X
X
Released
229

Related parts for PM5380-BI