LPC47M172 SMSC Corporation, LPC47M172 Datasheet - Page 67

no-image

LPC47M172

Manufacturer Part Number
LPC47M172
Description
ADVANCED I/O CONTROLLER WITH MOTHERBOARD GLUE LOGIC
Manufacturer
SMSC Corporation
Datasheet
Note:
6.17
SMSC/Non-SMSC Register Sets (Rev. 02-27-04)
If MT is set to “1” and the SC value is greater than the number of remaining formatted sectors on Side 0,
verifying will continue on Side 1 of the disk.
Format A Track
The Format command allows an entire track to be formatted. After a pulse from the nINDEX pin is
detected, the FDC starts writing data on the disk including gaps, address marks, ID fields, and data fields
per the IBM System 34 or 3740 format (MFM or FM respectively). The particular values that will be written
to the gap and data field are controlled by the values programmed into N, SC, GPL, and D which are
specified by the host during the command phase. The data field of the sector is filled with the data byte
specified by D. The ID field for each sector is supplied by the host; that is, four data bytes per sector are
needed by the FDC for C, H, R, and N (cylinder, head, sector number and sector size respectively).
After formatting each sector, the host must send new values for C, H, R and N to the FDC for the next
sector on the track. The R value (sector number) is the only value that must be changed by the host after
each sector is formatted. This allows the disk to be formatted with nonsequential sector addresses
(interleaving). This incrementing and formatting continues for the whole track until the FDC encounters a
pulse on the nINDEX pin again and it terminates the command.
Table 6.24 contains typical values for gap fields that are dependent upon the size of the sector and the
number of sectors on each track. Actual values can vary due to drive electronics.
MT
0
0
0
0
1
1
1
1
EC
0
0
1
1
0
0
1
1
Table 6.23 - Verify Command Result Phase Table
SC = DTL
EOT <= # Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
SC <= # Sectors Remaining AND
EOT <= # Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
SC = DTL
EOT <= # Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
SC <= # Sectors Remaining AND
EOT <= # Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
SC/EOT VALUE
DATASHEET
Page 67
Success Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Advanced I/O Controller with Motherboard GLUE Logic
TERMINATION RESULT
SMSC LPC47M172
Datasheet

Related parts for LPC47M172