P89v660/p89v662/p89v664 8-bit 80c51 5 V Low Power 16 Kb/32 Kb/64 Kb Flash Microcontroller With 512 B/1 Kb/2 Kb Ram, Dual I2c-bus, Spi
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
p89v660FA
Manufacturer:
PHI
Quantity:
5 530
Part Number:
p89v660FA
Manufacturer:
PHI
Quantity:
5 530
Part Number:
p89v660FA
Manufacturer:
NXP
Quantity:
12 388
Part Number:
p89v660FA
Manufacturer:
INT
Quantity:
5 600
Part Number:
p89v660FA
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
p89v660FA,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
p89v660FAЈ¬512
Manufacturer:
PHI
Quantity:
5 530
Part Number:
p89v660FBC,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
P89V660_662_664_2
Product data sheet
6.7.5 Framing error
6.7.6 More about UART mode 1
6.7.7 More about UART modes 2 and 3
Table 38.
Table 39.
Framing error (FE) is reported in the SCON.7 bit if SMOD0 (PCON.6) = 1. If SMOD0 = 0,
SCON.7 is the SM0 bit for the UART, it is recommended that SM0 is set up before SMOD0
is set to ‘1’.
Reception is initiated by a detected 1-to-0 transition at RXD. For this purpose RXD is
sampled at a rate of 16 times whatever baud rate has been established. When a transition
is detected, the divide-by-16 counter is immediately reset to align its rollovers with the
boundaries of the incoming bit times.
The 16 states of the counter divide each bit time into 16ths. At the 7th, 8th, and 9th
counter states of each bit time, the bit detector samples the value of RXD. The value
accepted is the value that was seen in at least 2 of the 3 samples. This is done for noise
rejection. If the value accepted during the first bit time is not 0, the receive circuits are
reset and the unit goes back to looking for another 1-to-0 transition. This is to provide
rejection of false start bits. If the start bit proves valid, it is shifted into the input shift
register, and reception of the rest of the frame will proceed.
The signal to load SBUF and RB8, and to set RI, will be generated if, and only if, the
following conditions are met at the time the final shift pulse is generated: (a) RI = 0, and
(b) Either SM2 = 0, or the received stop bit = 1.
If either of these two conditions is not met, the received frame is irretrievably lost. If both
conditions are met, the stop bit goes into RB8, the 8 data bits go into SBUF, and RI is
activated.
Reception is performed in the same manner as in mode 1.
Bit
3
2
1
0
SM0, SM1
0 0
0 1
1 0
1 1
SCON - Serial port control register (address 98H) bit description
SCON - Serial port control register (address 98H) SM0/SM1 mode definition
Symbol
TB8
RB8
TI
RI
UART mode
0: shift register
1: 8-bit UART
2: 9-bit UART
3: 9-bit UART
Rev. 02 — 29 January 2008
Description
The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear
by software as desired.
In Modes 2 and 3, is the 9th data bit that was received. In Mode 1, it
SM2 = 0, RB8 is the stop bit that was received. In Mode 0, RB8 is
undefined.
Transmit interrupt flag. Set by hardware at the end of the 8th bit time in
Mode 0, or at the stop bit in the other modes, in any serial
transmission. Must be cleared by software.
Receive interrupt flag. Set by hardware at the end of the 8th bit time in
Mode 0, or approximately halfway through the stop bit time in all other
modes. (See SM2 for exceptions). Must be cleared by software.
80C51 with 512 B/1 kB/2 kB RAM, dual I
Baud rate
CPU clock / 6
variable
CPU clock / 32 or CPU clock / 16
variable
P89V660/662/664
© NXP B.V. 2008. All rights reserved.