SAA7109 PHILIPS [NXP Semiconductors], SAA7109 Datasheet - Page 179

no-image

SAA7109

Manufacturer Part Number
SAA7109
Description
PC-CODEC
Manufacturer
PHILIPS [NXP Semiconductors]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAA7109AE
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
SAA7109AE
Quantity:
257
Part Number:
SAA7109AE/V1,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109AE/V1,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109AE/V1/G,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109AE/V1/G,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109E/V1
Manufacturer:
PHI
Quantity:
1 000
Part Number:
SAA7109H
Manufacturer:
AMI
Quantity:
51
Philips Semiconductors
18.2.5.4
Table 207 Status information scaler part; 8FH[7:0]; read only register
Note
1. Status information is unsynchronized and shows the actual status at the time of I
18.2.5.5
Table 208 Task handing control; register set A [90H[7:6]] and B [C0H[7:6]]; note 1
Note
1. X = don’t care.
Table 209 Task handling control; register set A [90H[5:3]] and B [C0H[5:3]]
2004 Mar 16
Output field ID is field ID from scaler input
Output field ID is task status flag, which changes every time an selected task
is activated (not synchronized to input field ID)
Scaler SAV/EAV byte bit 7 and task flag = 1, default
Scaler SAV/EAV byte bit 7 and task flag = 0
Active task is carried out directly
1 field is skipped before active task is carried out
... fields are skipped before active task is carried out
6 fields are skipped before active task is carried out
7 fields are skipped before active task is carried out
BIT
PC-CODEC
7
6
5
4
3
2
1
0
STATUS BIT
Subaddress 8FH
Subaddresses 90H and C0H
I
FIDSCO
PRDON
ERROF
2
FIDSCI
FFOV
C-BUS
XTRI
FFIL
ITRI
EVENT HANDLER CONTROL
EVENT HANDLER CONTROL
status on input pin XTRI, if not used for 3-state control, usable as hardware flag for software
use
status on input pin ITRI, if not used for 3-state control, usable as hardware flag for software
use
status of the internal ‘FIFO almost filled’ flag
status of the internal ‘FIFO overflow’ flag
copy of bit DPROG, can be used to detect power-up and start-up fails
error flag of scalers output formatter, normally set, if the output processing needs to be
interrupted, due to input/output data rate conflicts, e.g. if output data rate is much too low and
all internal FIFO capacity used
status of the field sequence ID at the scalers input
status of the field sequence ID at the scalers output, scaler processing dependent
179
FUNCTION
(1)
SAA7108E; SAA7109E
FSKP2
...
CONLH
0
0
1
1
2
C-bus read.
CONTROL BITS 7 AND 6
CONTROL BITS 5 TO 3
X
X
0
1
FSKP1
...
Product specification
0
0
1
1
OFIDC
X
X
0
1
FSKP0
...
0
1
0
1

Related parts for SAA7109