SAA7109 PHILIPS [NXP Semiconductors], SAA7109 Datasheet - Page 180

no-image

SAA7109

Manufacturer Part Number
SAA7109
Description
PC-CODEC
Manufacturer
PHILIPS [NXP Semiconductors]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAA7109AE
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
SAA7109AE
Quantity:
257
Part Number:
SAA7109AE/V1,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109AE/V1,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109AE/V1/G,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109AE/V1/G,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SAA7109E/V1
Manufacturer:
PHI
Quantity:
1 000
Part Number:
SAA7109H
Manufacturer:
AMI
Quantity:
51
Philips Semiconductors
Table 210 Task handling control; register set A [90H[2:0]] and B [C0H[2:0]]; note 1
Note
1. X = don’t care.
18.2.5.6
Table 211 X port formats and configuration; register set A [91H[7:3]] and B [C1H[7:3]]; note 1
Note
1. X = don’t care.
2004 Mar 16
Event handler triggers immediately after finishing a task
Event handler triggers with next V-sync
Event handler triggers with field ID = 0
Event handler triggers with field ID = 1
If active task is finished, handling is taken over by the next task
Active task is repeated once, before handling is taken over by the next task
SCALER INPUT FORMAT AND CONFIGURATION SOURCE
Only if XRQT[83H[2]] = 1: scaler input source reacts on
SAA7108E; SAA7109E request
Scaler input source is a continuous data stream, which cannot
be interrupted (must be logic 1 if SAA7108E; SAA7109E
decoder part is source of scaler or XRQT[83H[2]] = 0)
Scaler input source is data from decoder, data type is
provided according to Table 44
Scaler input source is Y-C
Scaler input source is raw digital CVBS from selected analog
channel, for backward compatibility only, further use is not
recommended
Scaler input source is raw digital CVBS (or 16-bit Y + C
no 16-bit output are active) from X port
SAV/EAV code bits 6 and 5 (F and V) may change between
SAV and EAV
SAV/EAV code bits 6 and 5 (F and V) are synchronized to
scalers output line start
SAV/EAV code bit 5 (V) and V gate on pin IGPV as generated
by the internal processing; see Fig.44
SAV/EAV code bit 5 (V) and V gate are inverted
PC-CODEC
Subaddresses 91H to 93H
SELECTION
B
EVENT HANDLER CONTROL
-C
R
data from X port
B
-C
180
R
, if
CONLV
X
X
X
X
X
X
X
X
0
1
HLDFV
CONTROL BITS 7 TO 3
X
X
X
X
X
X
X
X
0
1
SAA7108E; SAA7109E
SCSRC1 SCSRC0
RPTSK
CONTROL BITS 2 TO 0
X
X
X
X
X
X
X
X
X
X
0
1
0
0
1
1
Product specification
STRC1
X
X
X
X
X
X
X
X
0
0
1
1
0
1
0
1
SCRQE
STRC0
X
X
X
X
X
X
X
X
X
X
0
1
0
1
0
1

Related parts for SAA7109