KP-F1 Panduit Corp, KP-F1 Datasheet - Page 343

KIT FERRULE NONINS AWG22-14

KP-F1

Manufacturer Part Number
KP-F1
Description
KIT FERRULE NONINS AWG22-14
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule kitr
Datasheet

Specifications of KP-F1

Kit Type
Ferrule - Wire End
Values
370 pcs - Assorted Non-Insulated 22 ~ 14 AWG Ferrules
Kit Contents
500 Pieces Of F75-6, 400 Pieces Of F76-6 & F77-6, 300 Pieces Of F78-7, 200 Pieces Of F80-7
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
AWG dimensions represent typical outer cable diameter in inches.
Cable Fill Capacities for T-70 Raceway
This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to
the cable installation methods, straightness of cables, etc.
SPEC = 40% cable fill – The recommended design in cable capacity,
leaves room for future moves, adds, and changes.
2a.
2b.
5a.
5b.
1.
3.
4.
Cable fill #1: Raceway with
T-70: No devices.
T-70: Power and data using
the 3-sided hanging box and
device bracket.
T-70: Data only
(screw-on faceplates).
T-70: Data only
(snap-on faceplates).
T-70: Power and data using
the Workstation Outlet
Center
CR-SR-T70-WireFill1
Raceway Type and
A = 5.15 in.
Configuration
no devices.
Offset Box.
Cable fill #4: Data only using
communication faceplates.
horizontal sloped snap-on
2
A = 4.71 in.
Area
(In.²)
5.15
0.86
1.72
3.67
4.71
0.91
3.12
Fill
2
14 AWG 12 AWG 10 AWG
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
0.111
MAX
(UL Temp Rise Test)
24
14
14
Electrical Cables
THHN/T90
0.130
MAX
FILL
20
11
11
Cable fill #2: Power and data
A = .86 in.
using 3-sided hanging box
a
ELECTRICAL SOLUTIONS
and device bracket.
0.164
MAX
15
7
7
Cable fill #5: Power and data using the Workstation
2
Data Grade Cables
24 AWG/UTP CM
SPEC
(40%)
41
14
29
38
25
A = 1.72 in.
Cat 6. (4-pr.)
DIA. = 0.250
A = .91 in.
MAX for Data = 60% cable fill – The maximum cable quantity
based on cable interweaving and packing factors.
MAX for Power cable fill – The maximum of electrical cables
based on UL temperature rise test.
FILL
Outlet Center
(60%)
MAX
b
62
21
44
57
38
2
2
Data Grade Cables
Augmented Cat. 6
24 AWG/UTP CM
SPEC
(40%)
A = 3.12 in.
Offset Box.
24
17
22
14
a
8
DIA. = 0.330
FILL
(60%)
MAX
36
12
25
33
21
2
Cable fill #3: Data only using
communication faceplates.
vertical sloped screw-on
b
SPEC
(40%)
Audio/Video
DIA. = 0.275
34
11
24
31
21
A = 3.67 in.
RG6
FILL
(60%)
MAX
52
17
37
47
31
2
SPEC
(40%)
DIA. = 0.175
Fiber Optic
85
28
61
78
51
2 Strand
Cable
FILL
(60%)
MAX
128
117
42
91
77
C2.41
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.