KP-F1 Panduit Corp, KP-F1 Datasheet - Page 819

KIT FERRULE NONINS AWG22-14

KP-F1

Manufacturer Part Number
KP-F1
Description
KIT FERRULE NONINS AWG22-14
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule kitr
Datasheet

Specifications of KP-F1

Kit Type
Ferrule - Wire End
Values
370 pcs - Assorted Non-Insulated 22 ~ 14 AWG Ferrules
Kit Contents
500 Pieces Of F75-6, 400 Pieces Of F76-6 & F77-6, 300 Pieces Of F78-7, 200 Pieces Of F80-7
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Crimping Guidelines for Panduit
Compression Connectors
TAP Installation
1. Locate desired position of TAP along main wire run.
2. Strip insulation from wires to the length shown in
3. Position wires in the appropriate tap grooves.
4. For easier installation, apply one of the flame retardant
5. Install the correct dies (see page D3.94) into the crimping tool. Position the locator die into the stationary die
6. Position the TAP against the locator in the stationary die holder of the crimping tool.
7. After crimping, if desired, cut off the cable tie head or remove the entire cable tie. Note: In some cases, the
HTAP Cover Installation
1. If labels are being utilized, cut labels to the dimensions
2. Position the label(s) in the pockets inside the cover and
3. Position one cover half around the crimped connector
4. Install the two flame retardant cable ties (provided) in
Clear Cover
Part Number
CLRCVR1-1
CLRCVR2-1
CLRCVR3-1
Allow clearance for tap wires (and cover installation
if applicable). See clear cover table on page D3.13.
the TAP table on page D3.14. Use care to avoid
damaging the conductors.
cable ties (provided) around the wires and through the
slots in the TAP. The head of the cable tie must be positioned along the side of the TAP as shown in
Figure A. Tension and cut off excess length of tie. Additional cable ties may be used adjacent to the TAP to
secure the wires.
holder. Note: The color code and die index number shown on the HTAP and crimping dies must match.
cable tie head must be cut off in order for the crimped connector to fit inside the insulating cover.
shown below. Note: When using a Panduit
Pan-Ther
can be easily programmed to provide cut-off marks.
snap in the label retainer(s) as shown in Figure B.
Information can be marked on the matte finish label
retainers in lieu of using a separate label.
assembly. Align the second cover half with the first and
snap together.
the grooved areas on the cover. Tension and cut off
excess lengths of ties.
LS8E printer, the length dimensions
Label Height
Label Size Information
(Max.)
.38
.38
.38
(Wrap-Around
Label Length
Style)
1.56
1.87
2.37
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
Label Length
(Flat Style)
®
ELECTRICAL SOLUTIONS
1.00
1.25
1.75
®
StructuredGround
retainers provided
Non-adhesive
Two label
label may
be used
Cover allows for a clear
view of the label and
Note: Configuration of cover may differ
label protection
slightly from illustration.
Figure A
Figure B
Write-on surface
on label retainer
pockets provided
cable tie heads
Label
Pockets for
Crimping
Direction
Guides for
cable ties
Guides for
cable ties
D3.33
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.