KP-F1 Panduit Corp, KP-F1 Datasheet - Page 401

KIT FERRULE NONINS AWG22-14

KP-F1

Manufacturer Part Number
KP-F1
Description
KIT FERRULE NONINS AWG22-14
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule kitr
Datasheet

Specifications of KP-F1

Kit Type
Ferrule - Wire End
Values
370 pcs - Assorted Non-Insulated 22 ~ 14 AWG Ferrules
Kit Contents
500 Pieces Of F75-6, 400 Pieces Of F76-6 & F77-6, 300 Pieces Of F78-7, 200 Pieces Of F80-7
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Pan-Way
OFR20OFCR70**1P
OFR20OFCR70**4P
OFR20OFCR70**2P
OFR20OFCR70**4
OFR20OFCR70**2
OFR20OFCR70**1
OFR20CP
®
Office Furniture Raceway Fittings (continued)
Part Number
OFR20CPOB8
OFR20OFCR70OB4
OFR20OFCR70OB2
OFR20OFCR70OB1
OFR20OFCR70OB1P
OFR20OFCR70OB2P
OFR20OFCR70OB4P
‡For other colors, replace OB (Office Beige) with OS (Office Slate), OG (Office Gray), or MT (Medium Tone).
Computer printable labels found on pages E2.4 and E2.5
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
Communication pole. Allows for data cable entry
into office furniture raceway from suspended
ceiling. 8' pole allows maximum 7' distance from
top of furniture partition to ceiling.
Must be used with OFR20MPT**.
Note: Not intended for use at intersection
of furniture panels.
Four cubicle drop fitting. Allows the transition
from office furniture raceway run horizontally
along partition wall to office furniture corner
raceway mounted vertically in four cubicles at
the intersection of partitions. Fitting maintains 1"
minimum bend radius of cabling. Supplied with
adhesive tape.
Two cubicle drop fitting. Allows the transition
from office furniture raceway run horizontally
along partition wall to office furniture corner
raceway mounted vertically in two cubicles at
the intersection of partitions. Fitting maintains 1"
minimum bend radius of cabling. Supplied with
adhesive tape.
One cubicle drop fitting. Allows the transition
from office furniture raceway run horizontally
along partition wall to office furniture corner
raceway mounted vertically in one cubicle at the
intersection of partitions. Fitting maintains 1"
minimum bend radius of cabling. Supplied with
adhesive tape.
One cubicle drop bypass fitting. Allows the
transition from office furniture raceway run
horizontally along partition wall, around existing
furniture pole, to office furniture corner raceway
mounted vertically in one cubicle at the
intersection of partitions. Fitting maintains 1"
minimum bend radius of cabling. Supplied with
adhesive tape.
Two cubicle drop bypass fitting. Allows the
transition from office furniture raceway run
horizontally along partition wall, around existing
furniture pole, to office furniture corner raceway
mounted vertically in two cubicles at the
intersection of partitions. Fitting maintains 1"
minimum bend radius of cabling. Supplied with
adhesive tape.
Four cubicle drop bypass fitting. Allows the
transition from office furniture raceway run
horizontally along partition wall, around existing
furniture pole, to office furniture corner raceway
mounted vertically in four cubicles at the
intersection of partitions. Fitting maintains 1"
minimum bend radius of cabling. Supplied with
adhesive tape.
Part Description
Table continues on page C2.100
Required
Labels
Color‡
Office
Beige
Office
Beige
Office
Beige
Office
Beige
Office
Beige
Office
Beige
Office
Beige
Pkg.
Std.
Qty.
1
1
1
1
1
1
1
Std.
Ctn.
Qty.
10
10
10
10
10
10
C2.99
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.