TOOLSTICK540DC Silicon Laboratories Inc, TOOLSTICK540DC Datasheet - Page 43

DAUGHTER CARD TOOLSTICK F540

TOOLSTICK540DC

Manufacturer Part Number
TOOLSTICK540DC
Description
DAUGHTER CARD TOOLSTICK F540
Manufacturer
Silicon Laboratories Inc
Series
ToolStickr
Type
MCUr

Specifications of TOOLSTICK540DC

Contents
Daughter Card
Processor To Be Evaluated
C8051F54x
Processor Series
C8051F54x
Interface Type
USB
Operating Supply Voltage
2.7 V to 3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F54x
For Use With
336-1345 - TOOLSTICK BASE ADAPTER336-1182 - ADAPTER USB DEBUG FOR C8051FXXX
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1717
SFR Definition 5.8. ADC0TK: ADC0 Tracking Mode Select
SFR Address = 0xBA; SFR Page = 0x00;
5.4. Programmable Window Detector
The ADC Programmable Window Detector continuously compares the ADC0 output registers to user-pro-
grammed limits, and notifies the system when a desired condition is detected. This is especially effective in
an interrupt-driven system, saving code space and CPU bandwidth while delivering faster system
response times. The window detector interrupt flag (AD0WINT in register ADC0CN) can also be used in
polled mode. The ADC0 Greater-Than (ADC0GTH, ADC0GTL) and Less-Than (ADC0LTH, ADC0LTL)
registers hold the comparison values. The window detector flag can be programmed to indicate when mea-
sured data is inside or outside of the user-programmed limits, depending on the contents of the ADC0
Less-Than and ADC0 Greater-Than registers.
Name
Reset
Bit
7:4
3:2
1:0
Type
Bit
AD0PWR[3:0] ADC0 Burst Power-Up Time.
AD0TM[1:0]
AD0TK[1:0]
Name
7
1
AD0PWR
For BURSTEN = 0: ADC0 Power state controlled by AD0EN
For BURSTEN = 1, AD0EN = 1: ADC0 remains enabled and does not enter the
very low power state
For BURSTEN = 1, AD0EN = 0: ADC0 enters the very low power state and is
enabled after each convert start signal. The Power-Up time is programmed accord-
ing the following equation:
ADC0 Tracking Mode Enable Select Bits.
00: Reserved.
01: ADC0 is configured to Post-Tracking Mode.
10: ADC0 is configured to Pre-Tracking Mode.
11: ADC0 is configured to Dual Tracking Mode.
ADC0 Post-Track Time.
00: Post-Tracking time is equal to 2 SAR clock cycles + 2 FCLK cycles.
01: Post-Tracking time is equal to 4 SAR clock cycles + 2 FCLK cycles.
10: Post-Tracking time is equal to 8 SAR clock cycles + 2 FCLK cycles.
11: Post-Tracking time is equal to 16 SAR clock cycles + 2 FCLK cycles.
AD0PWR[3:0]
6
1
R/W
=
5
1
Tstartup
----------------------- - 1
200ns
Rev. 1.1
4
1
or
Tstartup
Function
3
1
AD0TM[1:0]
R/W
=
AD0PWR
2
1
C8051F54x
1
1
+
AD0TK[1:0]
1
200ns
R/W
0
1
43

Related parts for TOOLSTICK540DC